This study investigated the effectiveness of heat shield placement locations during the rework process to avoid thermal and mechanical damage to adjacent ball grid array components and their solder joints on double-sided printed circuit board assembly. Three types of heat shield placement locations were used: sample X, individual heat shield placement on adjacent components of the rework location; sample Y, a U-shaped, and sample Z, a square-shaped heat shield placed respectively at the heat source location. The dye and pull test results, infrared thermography, and temperature measurements were analysed to understand the relationship between the location of the heat shield and solder joint damage during rework. Heat shield placement at the heat source location on the reworked component can reduce the peak temperatures on the adjacent rework component locations by up to 8.18%. The peak temperatures of the centre and corner of the BGA component can be maintained below 195 °C and 210 °C, respectively to improve the adjacent rework component locations' solder joint quality by reducing solder joint damage by more than 50% solder cracks. This is useful for thermal management during rework involving high-density ball grid array component placements on double-sided printed circuit board assembly.

摘要

本研究调查了返工过程中热屏蔽放置位置对避免双面印刷电路板组件上相邻球栅阵列组件及其焊点受到热和机械损伤的有效性。使用了三种热屏蔽放置位置:样品X,在返工位置的相邻组件上单独放置热屏蔽;样品Y,呈U形;样品Z,分别在热源位置放置方形热屏蔽。对染色和拉力测试结果、红外热成像和温度测量进行了分析,以了解返工过程中热屏蔽位置与焊点损伤之间的关系。在返工组件的热源位置放置热屏蔽可将相邻返工组件位置的峰值温度降低多达8.18%。BGA组件中心和角落的峰值温度可分别保持在195°C和210°C以下,通过减少超过50%的焊点裂纹来减少焊点损伤,从而提高相邻返工组件位置的焊点质量。这对于涉及双面印刷电路板组件上高密度球栅阵列组件放置的返工过程中的热管理很有用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/15f2/9448760/2435f5b4f736/41598_2022_19436_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验