Suppr超能文献

[F]FE-PE2I正电子发射断层扫描(PET)是[I]FP-CIT单光子发射计算机断层扫描(SPECT)的一种可行替代方法,用于临床诊断不明确的帕金森病患者的多巴胺转运体成像。

[F]FE-PE2I PET is a feasible alternative to [I]FP-CIT SPECT for dopamine transporter imaging in clinically uncertain parkinsonism.

作者信息

Marner Lisbeth, Korsholm Kirsten, Anderberg Lasse, Lonsdale Markus N, Jensen Mads Radmer, Brødsgaard Eva, Denholt Charlotte L, Gillings Nic, Law Ian, Friberg Lars

机构信息

Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital Bispebjerg, Bispebjerg Bakke 23, Copenhagen, Denmark.

Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.

出版信息

EJNMMI Res. 2022 Sep 7;12(1):56. doi: 10.1186/s13550-022-00930-x.

Abstract

BACKGROUND

Dopamine transporter (DAT) imaging of striatum is clinically used in Parkinson's disease (PD) and neurodegenerative parkinsonian syndromes (PS) especially in the early disease stages. The aim of the present study was to evaluate the diagnostic performance of the recently developed tracer for DAT imaging [F]FE-PE2I PET/CT to the reference standard [I]FP-CIT SPECT.

METHODS

Ninety-eight unselected patients referred for DAT imaging were included prospectively and consecutively and evaluated with [F]FE-PE2I PET/CT and [I]FP-CIT SPECT on two separate days. PET and SPECT scans were categorized independently by two blinded expert readers as either normal, vascular changes, or mixed. Semiquantitative values were obtained for each modality and compared regarding effect size using Glass' delta.

RESULTS

Fifty-six of the [I]FP-CIT SPECT scans were considered abnormal (52 caused by PS, 4 by infarctions). Using [F]FE-PE2I PET/CT, 95 of the 98 patients were categorized identically to SPECT as PS or non-PS with a sensitivity of 0.94 [0.84-0.99] and a specificity of 1.00 [0.92-1.00]. Inter-reader agreement for [F]FE-PE2I PET with a kappa of 0.97 [0.89-1.00] was comparable to the agreement for [I]FP-CIT SPECT of 0.96 [0.76-1.00]. Semiquantitative values for short 10-min reconstructions of [F]FE-PE2I PET/CT were comparable to longer reconstructions. The effect size for putamen/caudate nucleus ratio was significantly increased using PET compared to SPECT.

CONCLUSIONS

The high correspondence of [F]FE-PE2I PET compared to reference standard [I]FP-CIT SPECT establishes [F]FE-PE2I PET as a feasible PET tracer for clinical use with favourable scan logistics.

摘要

背景

纹状体多巴胺转运体(DAT)成像在帕金森病(PD)和神经退行性帕金森综合征(PS)的临床诊断中应用广泛,尤其在疾病早期。本研究旨在评估最近开发的用于DAT成像的示踪剂[F]FE - PE2I PET/CT相对于参考标准[I]FP - CIT SPECT的诊断性能。

方法

前瞻性连续纳入98例因DAT成像而转诊的未经筛选的患者,并在两个不同日期分别接受[F]FE - PE2I PET/CT和[I]FP - CIT SPECT检查。PET和SPECT扫描由两位盲法专家读者独立分类为正常、血管改变或混合情况。获取每种检查方式的半定量值,并使用格拉斯δ值比较效应大小。

结果

[I]FP - CIT SPECT扫描中有56例被认为异常(52例由PS引起,4例由梗死引起)。使用[F]FE - PE2I PET/CT时,98例患者中有95例与SPECT对PS或非PS的分类相同,灵敏度为0.94[0.84 - 0.99],特异性为1.00[0.92 - 1.00]。[F]FE - PE2I PET的阅片者间一致性kappa值为0.97[0.89 - 1.00],与[I]FP - CIT SPECT的一致性0.96[0.76 - 1.00]相当。[F]FE - PE2I PET/CT短时间10分钟重建的半定量值与长时间重建相当。与SPECT相比,PET检测壳核/尾状核比值的效应大小显著增加。

结论

与参考标准[I]FP - CIT SPECT相比,[F]FE - PE2I PET具有高度一致性,这确立了[F]FE - PE2I PET作为一种可行的PET示踪剂,具有良好的扫描流程,可用于临床。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/521e/9452620/efe840fe1534/13550_2022_930_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验