First Department of Neurology, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic.
Multimodal and Functional Neuroimaging Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic.
Sci Rep. 2022 Sep 7;12(1):15158. doi: 10.1038/s41598-022-19121-8.
The objective was to determine the optimal combination of multimodal imaging methods (IMs) for localizing the epileptogenic zone (EZ) in patients with MR-negative drug-resistant epilepsy. Data from 25 patients with MR-negative focal epilepsy (age 30 ± 10 years, 16M/9F) who underwent surgical resection of the EZ and from 110 healthy controls (age 31 ± 9 years; 56M/54F) were used to evaluate IMs based on 3T MRI, FDG-PET, HD-EEG, and SPECT. Patients with successful outcomes and/or positive histological findings were evaluated. From 38 IMs calculated per patient, 13 methods were selected by evaluating the mutual similarity of the methods and the accuracy of the EZ localization. The best results in postsurgical patients for EZ localization were found for ictal/ interictal SPECT (SISCOM), FDG-PET, arterial spin labeling (ASL), functional regional homogeneity (ReHo), gray matter volume (GMV), cortical thickness, HD electrical source imaging (ESI-HD), amplitude of low-frequency fluctuation (ALFF), diffusion tensor imaging, and kurtosis imaging. Combining IMs provides the method with the most accurate EZ identification in MR-negative epilepsy. The PET, SISCOM, and selected MRI-post-processing techniques are useful for EZ localization for surgical tailoring.
目的是确定多模态成像方法(IMs)的最佳组合,以定位磁共振阴性耐药性癫痫患者的致痫区(EZ)。使用来自 25 名接受 EZ 切除术的磁共振阴性局灶性癫痫患者(年龄 30±10 岁,16M/9F)和 110 名健康对照者(年龄 31±9 岁;56M/54F)的数据来评估基于 3T MRI、FDG-PET、HD-EEG 和 SPECT 的 IMs。评估了有手术结果和/或阳性组织学发现的患者。从每位患者计算的 38 种 IM 中,通过评估方法的相互相似性和 EZ 定位的准确性,选择了 13 种方法。在术后患者中,用于 EZ 定位的最佳结果是发作期/发作间期 SPECT(SISCOM)、FDG-PET、动脉自旋标记(ASL)、功能区域同质性(ReHo)、灰质体积(GMV)、皮质厚度、HD 电源成像(ESI-HD)、低频波动幅度(ALFF)、弥散张量成像和峰度成像。结合 IMs 可提供最准确的磁共振阴性癫痫 EZ 识别方法。PET、SISCOM 和选定的 MRI 后处理技术对于手术定制的 EZ 定位很有用。