Dybowska-Józefiak Monika, Wesołowska Maria
Faculty of Civil and Environmental Engineering and Architecture, Bydgoszcz University of Science and Technology, 85-796 Bydgoszcz, Poland.
Materials (Basel). 2022 Aug 29;15(17):5963. doi: 10.3390/ma15175963.
This paper discusses changes in the microstructure and water absorption of thin-coat mineral-based plasters after prolonged exposure to the external environment and infected with biological corrosion. The results of laboratory and field tests for external thermal insulation composite system Styrofoam-based plasters are presented. The test samples were taken after 6 years of exposure to the external environment. The microstructure parameters such as porosity distribution and water absorption of the plasters were evaluated. The pore size ranges that were sensitive to frost corrosion and capillary flow were separated in the porosity distribution. Based on the porosity and absorption changes, it was found that biological corrosion interferes with the microstructure of the thin-coat mineral-based plasters on the expanded polystyrene substrate.
本文讨论了薄涂层矿物基灰泥在长期暴露于外部环境并受到生物腐蚀后微观结构和吸水性的变化。给出了基于聚苯乙烯泡沫塑料的外墙外保温复合系统灰泥的实验室和现场测试结果。测试样品是在暴露于外部环境6年后采集的。评估了灰泥的孔隙率分布和吸水性等微观结构参数。在孔隙率分布中分离出了对冻融腐蚀和毛细流动敏感的孔径范围。基于孔隙率和吸水性的变化,发现生物腐蚀会干扰膨胀聚苯乙烯基材上薄涂层矿物基灰泥的微观结构。