Abstract

OBJECTIVE

Precurved cochlear implant (CI) electrode arrays have demonstrated superior audiometric outcomes compared with straight electrodes in a handful of studies. However, previous comparisons have often failed to account for preoperative hearing and age. This study compares hearing outcomes for precurved and straight electrodes by a single manufacturer while controlling for these and other factors in a large cohort.

STUDY DESIGN

Retrospective cohort study.

SETTING

Tertiary academic medical center.

PATIENTS

Two hundred thirty-one adult CI recipients between 2015 and 2021 with cochlear (Sydney, Australia) 522/622 (straight) or 532/632 (precurved) electrode arrays.

INTERVENTIONS

Postactivation speech recognition and audiometric testing.

MAIN OUTCOME MEASURES

Speech recognition testing (consonant-nucleus-consonant word [CNCw] and AzBio) was collected at 6 and 12 months postactivation. Hearing preservation was characterized by a low-frequency pure-tone average shift, or the change between preoperative and postoperative low-frequency pure-tone average.

RESULTS

Two hundred thirty-one patients (253 ears) with 6-month and/or 12-month CNCw or AzBio testing were included. One hundred forty-nine (59%) and 104 (41%) ears were implanted with straight and precurved electrode arrays, respectively. Average age at implantation was 70 years (interquartile range [IQR], 58-77 y). There was no significant difference in mean age between groups. CNCw scores were significantly different ( p = 0.001) between straight (51%; IQR, 36-67%) and precurved arrays (64%; IQR, 48-72%). AzBio scores were not significantly different ( p = 0.081) between straight (72%; IQR, 51-87%) and precurved arrays (81%; IQR, 57-90%). Controlling for age, race, sex, preoperative hearing, and follow-up time, precurved electrode arrays performed significantly better on CNCw (b = 10.0; 95% confidence interval, 4.2-16.0; p < 0.001) and AzBio (b = 8.9; 95% confidence interval, 1.8-16.0;, p = 0.014) testing. Hearing preservation was not different between electrodes on adjusted models.

CONCLUSION

During the study period, patients undergoing placement of precurved electrode arrays had significantly higher CNC and AzBio scores than patients receiving straight electrodes, even after controlling for age, preoperative hearing, and follow-up time.

PROFESSIONAL PRACTICE GAP AND EDUCATIONAL NEED

Understanding the difference in audiometric outcomes between precurved and straight electrode arrays will help to guide electrode selection.

LEARNING OBJECTIVE

To understand differences in speech recognition scores postoperatively by electrode array type (precurved versus straight).

DESIRED RESULT

To demonstrate a difference in hearing performance postoperatively by electrode type.

LEVEL OF EVIDENCE

III.

INDICATE IRB OR IACUC

Approved by the Institutional IRB (090155).

摘要

目的

在少数研究中,预弯式人工耳蜗(CI)电极阵列与直电极相比,已显示出更好的听力测量结果。然而,以往的比较往往没有考虑术前听力和年龄因素。本研究在一个大型队列中,对单一制造商生产的预弯式和直电极的听力结果进行比较,并对这些因素及其他因素进行控制。

研究设计

回顾性队列研究。

研究地点

三级学术医疗中心。

患者

2015年至2021年间的231名成年人工耳蜗植入者,植入了科利耳(澳大利亚悉尼)522/622(直电极)或532/632(预弯电极)电极阵列。

干预措施

激活后言语识别和听力测试。

主要观察指标

在激活后6个月和12个月收集言语识别测试(辅音-核-辅音单词[CNCw]和AzBio)。听力保留以低频纯音平均移行来表征,即术前和术后低频纯音平均的变化。

结果

纳入了231例患者(253耳)进行6个月和/或12个月的CNCw或AzBio测试。分别有149耳(59%)和104耳(41%)植入了直电极阵列和预弯电极阵列。植入时的平均年龄为70岁(四分位间距[IQR],58 - 77岁)。两组间平均年龄无显著差异。直电极阵列(51%;IQR,36 - 67%)和预弯电极阵列(64%;IQR,48 - 72%)的CNCw得分有显著差异(p = 0.001)。直电极阵列(72%;IQR,51 - 87%)和预弯电极阵列(81%;IQR,57 - 90%)的AzBio得分无显著差异(p = 0.081)。在控制年龄、种族、性别、术前听力和随访时间后,预弯电极阵列在CNCw(b = 10.0;95%置信区间,4.2 - 16.0;p < 0.001)和AzBio(b = 8.9;95%置信区间,1.8 - 16.0;p = 0.014)测试中表现明显更好。在调整模型中,电极间的听力保留情况无差异。

结论

在研究期间,即使在控制了年龄、术前听力和随访时间后,接受预弯电极阵列植入的患者的CNC和AzBio得分仍显著高于接受直电极的患者。

专业实践差距与教育需求

了解预弯式和直电极阵列在听力测量结果上的差异将有助于指导电极选择。

学习目标

了解术后不同类型电极阵列(预弯式与直电极)的言语识别得分差异。

预期结果

证明术后不同电极类型的听力表现存在差异。

证据级别

III级。

说明是否经机构审查委员会(IRB)或机构动物护理与使用委员会(IACUC)批准:经机构IRB批准(090155)。