In vitro study of the effect of implant position and attachment type on stress distribution of implant-assisted removable partial dentures.

作者信息

Tun Naing Sai, Kanazawa Manabu, Hada Tamaki, Iwaki Maiko, Komagamine Yuriko, Miyayasu Anna, Uehara Yoko, Minakuchi Shunsuke

机构信息

Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan.

Department of Digital Dentistry, Tokyo Medical and Dental University, Tokyo, Japan.

出版信息

J Dent Sci. 2022 Oct;17(4):1697-1703. doi: 10.1016/j.jds.2021.11.018. Epub 2022 Mar 15.

Abstract

BACKGROUND/PURPOSE: Implant assisted removable partial dentures (IARPDs) improved biomechanical behavior of removable partial dentures (RPDs), but information of the effect of attachment type and implant position is limited. This study aimed to investigate the effect of implant position and attachment type on the stress distribution of IARPDs.

MATERIAL AND METHODS

Four implants, 10 mm in length and 4.1 mm in diameter, were bilaterally placed close to first premolar and second molar regions of a mandibular Kennedy class I model having artificial dentition from canine to canine, vertical to the occlusal plane. Five IARPDs were fabricated to accommodate locator and magnetic attachments. Strain gauges were placed on the model surface to measure the strain around implants during loading. Unilateral vertical loading was applied to the right first molar area with magnitude of 120 N and crosshead speed of 10 mm/min. Measurements were recorded under following conditions: premolar IARPDs with locator or magnetic attachments, molar IARPDs with locator or magnetic attachments. Two-way multiple analysis of variance was performed to compare the maximum principal strain (MPS) around the implants with a significance level of 0.05.

RESULTS

Implant position had significant effect on the MPS of IARPD on loading and nonloading sides while attachment type only significant on nonloading side. Molar implants showed larger MPS than premolar implants with both locator and magnetic attachments during unilateral loading.

CONCLUSION

The stress distribution of the IARPD is significantly affected by implant position wherein anteriorly placed implants exhibit lower MPS than relatively posteriorly placed implants.

摘要

背景/目的:种植体辅助可摘局部义齿(IARPD)改善了可摘局部义齿(RPD)的生物力学行为,但关于附着类型和种植体位置影响的信息有限。本研究旨在探讨种植体位置和附着类型对IARPD应力分布的影响。

材料与方法

在下颌Kennedy I类模型双侧靠近第一前磨牙和第二磨牙区域植入4枚长度为10mm、直径为4.1mm的种植体,该模型人工牙列覆盖双侧尖牙,种植体垂直于咬合平面。制作5副IARPD,分别采用定位器和磁性附着体。在模型表面放置应变片以测量加载过程中种植体周围的应变。对右侧第一磨牙区域施加120N的单侧垂直加载,十字头速度为10mm/min。在以下条件下记录测量值:带有定位器或磁性附着体的前磨牙IARPD、带有定位器或磁性附着体的磨牙IARPD。采用双向多因素方差分析比较种植体周围的最大主应变(MPS),显著性水平为0.05。

结果

种植体位置对加载侧和非加载侧IARPD的MPS有显著影响,而附着类型仅对非加载侧有显著影响。在单侧加载过程中,采用定位器和磁性附着体时,磨牙种植体的MPS均大于前磨牙种植体。

结论

IARPD的应力分布受种植体位置显著影响,其中靠前放置的种植体比相对靠后放置的种植体表现出更低的MPS。