Suppr超能文献

正畸加载前后微型螺钉种植体龈沟液中巨噬细胞集落刺激因子的定量分析。

A quantitative analysis of macrophage-colony-stimulating factor in peri-miniscrew implant crevicular fluid before and after orthodontic loading.

作者信息

Katyal Sakshi, Kharbanda Om Prakash, Duggal Ritu, Samrit Vilas D

出版信息

Angle Orthod. 2023 Mar 1;93(2):222-227. doi: 10.2319/062322-445.1.

Abstract

OBJECTIVES

To analyze macrophage-colony-stimulating factor (M-CSF), a bone remodeling biomarker in the peri-miniscrew implant crevicular fluid (PMICF) after insertion and orthodontic loading.

MATERIALS AND METHODS

This prospective study included 40 miniscrew implant (MSI) sites in 10 subjects undergoing fixed orthodontic mechanotherapy utilizing miniscrew anchorage. After dental alignment, miniscrews were inserted between the second premolar and first molar roots. After 21 days of insertion, MSIs were direct loaded with closed-coil springs (200 g force) for en masse retraction of anterior teeth. PMICF was collected with Periopaper™ strips from the gingival crevice around MSIs at six time points (T1-T6: 1 hour, 1 day, 21 days postinsertion, and 7, 21, and 42 days postloading). PMICF was quantified for M-CSF by enzyme-linked immunosorbent assay. Paired comparison of mean M-CSF concentrations before and after loading stages (T1-T6) was made using the Wilcoxon signed-rank test.

RESULTS

The mean M-CSF concentration showed a significant peak at T3 (21 days postinsertion; 12.646 pg/mL; T1 vs T3: P < .0001). After orthodontic loading of miniscrews, M-CSF levels increased to 13.570 pg/mL at T4 (7 days after loading; T1 vs T4: P < .001) and maintained at a plateau to T5 (21 days postloading; 11.994 pg/mL). However, the difference between preloading and postloading was not statistically significant (T3 vs T4).

CONCLUSIONS

The maximum M-CSF activity around MSIs was observed at around 3 weeks of miniscrew insertion, suggesting underlying bone remodeling after surgical injury. However, orthodontic force on MSIs did not cause any significant surge in M-CSF levels postloading.

摘要

目的

分析微型螺钉种植体植入及正畸加力后,龈沟液(PMICF)中骨重塑生物标志物巨噬细胞集落刺激因子(M-CSF)的变化情况。

材料与方法

本前瞻性研究纳入了10例接受微型螺钉支抗固定正畸治疗的患者,共40个微型螺钉种植体植入位点。排齐牙齿后,在第二前磨牙和第一磨牙牙根之间植入微型螺钉。植入21天后,用闭合曲弹簧(200g力)对微型螺钉进行直接加力,整体内收前牙。在六个时间点(T1-T6:植入后1小时、1天、21天,以及加力后7天、21天和42天),用Periopaper™试纸条从微型螺钉周围的龈沟采集PMICF。通过酶联免疫吸附测定法定量检测PMICF中的M-CSF。使用Wilcoxon符号秩检验对加力前后阶段(T1-T6)的平均M-CSF浓度进行配对比较。

结果

平均M-CSF浓度在T3(植入后21天;12.646 pg/mL;T1与T3比较:P <.0001)时出现显著峰值。微型螺钉正畸加力后,M-CSF水平在T4(加力后7天;13.570 pg/mL;T1与T4比较:P <.001)时升高,并维持在平台期至T5(加力后21天;11.994 pg/mL)。然而,加力前后的差异无统计学意义(T3与T4比较)。

结论

微型螺钉植入约3周时,微型螺钉周围的M-CSF活性最高,提示手术损伤后存在潜在的骨重塑。然而,微型螺钉上的正畸力在加力后并未导致M-CSF水平出现任何显著升高。

相似文献

2
Levels of TGF-β1 in peri-miniscrew implant crevicular fluid.
J Oral Biol Craniofac Res. 2020 Apr-Jun;10(2):93-98. doi: 10.1016/j.jobcr.2020.03.002. Epub 2020 Mar 6.
3
A review of biomarkers in peri-miniscrew implant crevicular fluid (PMICF).
Prog Orthod. 2017 Nov 27;18(1):42. doi: 10.1186/s40510-017-0195-8.
5
A study of interleukin 1β levels in peri-miniscrew crevicular fluid (PMCF).
Prog Orthod. 2014 Apr 1;15(1):30. doi: 10.1186/s40510-014-0030-4.
7
Chondroitin sulphate (WF6 epitope) levels in peri-miniscrew implant crevicular fluid during orthodontic loading.
Eur J Orthod. 2010 Feb;32(1):60-5. doi: 10.1093/ejo/cjp056. Epub 2009 Sep 13.
9
OPG and RANKL levels around miniscrew implants during orthodontic tooth movement.
Am J Orthod Dentofacial Orthop. 2013 Aug;144(2):203-9. doi: 10.1016/j.ajodo.2013.02.028.
10
Assessment of stability of orthodontic mini-implants under orthodontic loading: A computed tomography study.
Indian J Dent Res. 2015 May-Jun;26(3):237-43. doi: 10.4103/0970-9290.162874.

引用本文的文献

1
Temporary Anchorage Devices in Clear Aligner Therapy: A Systematic Review.
Bioengineering (Basel). 2025 May 15;12(5):531. doi: 10.3390/bioengineering12050531.

本文引用的文献

1
The influence of M-CSF on fracture healing in a mouse model.
Sci Rep. 2021 Nov 16;11(1):22326. doi: 10.1038/s41598-021-01673-w.
3
MicroRNA-34 expression in gingival crevicular fluid correlated with orthodontic tooth movement.
Angle Orthod. 2020 Sep 1;90(5):702-706. doi: 10.2319/090219-574.1.
4
Levels of TGF-β1 in peri-miniscrew implant crevicular fluid.
J Oral Biol Craniofac Res. 2020 Apr-Jun;10(2):93-98. doi: 10.1016/j.jobcr.2020.03.002. Epub 2020 Mar 6.
5
Gingival Crevicular Fluid: An Overview.
J Pharm Bioallied Sci. 2019 May;11(Suppl 2):S135-S139. doi: 10.4103/JPBS.JPBS_56_19.
6
Miniscrews failure rate in orthodontics: systematic review and meta-analysis.
Eur J Orthod. 2018 Sep 28;40(5):519-530. doi: 10.1093/ejo/cjx093.
7
A review of biomarkers in peri-miniscrew implant crevicular fluid (PMICF).
Prog Orthod. 2017 Nov 27;18(1):42. doi: 10.1186/s40510-017-0195-8.
8
Immunological Responses to Total Hip Arthroplasty.
J Funct Biomater. 2017 Aug 1;8(3):33. doi: 10.3390/jfb8030033.
9
Osteoclasts: New Insights.
Bone Res. 2013 Mar 29;1(1):11-26. doi: 10.4248/BR201301003. eCollection 2013 Mar.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验