即刻与延迟正畸加载过程中微型种植体周围龈沟液中基质金属蛋白酶-8水平——一项双侧对照研究

Matrix Metalloproteinase-8 Levels in Peri-Miniscrew Crevicular Fluid During Immediate and Delayed Orthodontic Loading--A Split-Mouth Study.

作者信息

Khot Dhanashree D, Bhosale Veera I, Kamyab Seyedeh Sara, Moghe Alpana Subodh, Patil Amol Somaji

出版信息

Int J Oral Maxillofac Implants. 2023 Jan-Feb;38(1):130-135. doi: 10.11607/jomi.9705.

Abstract

To compare the matrix metalloproteinase-8 (MMP-8) levels in the peri-miniscrew implant crevicular fluid (PMCF) of immediate-loaded and delayed-loaded miniscrew implants at different time intervals. Titanium orthodontic miniscrews were placed bilaterally in the attached gingiva of 15 patients between the maxillary second premolar and maxillary first molar for en masse retraction. This split-mouth study was designed to have an immediate-loaded miniscrew on one side and a delayed-loaded miniscrew on the other side that was loaded 8 days after miniscrew placement. PMCF was collected from the mesiobuccal aspects of the immediate-loaded implants at 24 hours, 8 days, and 28 days after loading, and from the delayed-loaded miniscrew implants at 24 hours and 8 days before loading and 24 hours and 28 days after loading. An enzyme-linked immunosorbent assay kit was used to assess MMP-8 levels in the PMCF samples. Unpaired test, ANOVA F-test, and Tukey post hoc test were used to evaluate data at the < .05 level. Although there were slight alterations in the MMP-8 levels in the PMCF over time, there was no statistically significant difference in the MMP-8 levels between groups. There was a statistically significant decrease in the levels of MMP-8 between 24 hours after miniscrew placement and 28 days after loading on the delayed-loaded side ( < .05). The MMP-8 levels did not vary much between immediate-loaded and delayed-loaded miniscrew implants as a result of the force application. However, there was no significant difference between immediate loading and delayed loading in terms of biologic response to mechanical stress. The increase in MMP-8 levels after 24 hours post-miniscrew insertion, as well as the subsequent gradual reduction over the course of the study period in both immediate and delayed groups after loading, is probably due to the bone adapting to stimuli.

摘要

比较即刻加载和延迟加载微型螺钉种植体在不同时间间隔时,种植体周围龈沟液(peri - miniscrew implant crevicular fluid,PMCF)中基质金属蛋白酶 - 8(matrix metalloproteinase - 8,MMP - 8)的水平。将正畸钛制微型螺钉双侧植入15例患者上颌第二前磨牙与上颌第一磨牙之间的附着龈,用于整体内收。本双盲研究设计为一侧为即刻加载微型螺钉,另一侧为延迟加载微型螺钉,延迟加载微型螺钉在植入后8天加载。在加载后24小时、8天和28天从即刻加载种植体的近中颊侧收集PMCF,在加载前24小时和8天以及加载后24小时和28天从延迟加载微型螺钉种植体收集PMCF。使用酶联免疫吸附测定试剂盒评估PMCF样本中的MMP - 8水平。采用非配对t检验、方差分析F检验和Tukey事后检验在α < 0.05水平评估数据。尽管PMCF中MMP - 8水平随时间有轻微变化,但两组间MMP - 8水平无统计学显著差异。在延迟加载侧,微型螺钉植入后24小时至加载后28天,MMP - 8水平有统计学显著下降(α < 0.05)。由于施加力的原因,即刻加载和延迟加载微型螺钉种植体之间的MMP - 8水平变化不大。然而,在对机械应力的生物学反应方面,即刻加载和延迟加载之间没有显著差异。微型螺钉植入后24小时MMP - 8水平升高,以及在研究期间即刻加载组和延迟加载组加载后MMP - 8水平随后逐渐降低,可能是由于骨对刺激的适应。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验