Straughan J L, Cathcart-Rake W F, Shoeman D W, Azarnoff D L
J Chromatogr. 1978 Nov 1;146(3):473-80. doi: 10.1016/s0378-4347(00)81206-2.
Chlordiazepoxide and its 4 major metabolites were assayed after separation by thin-layer chromatography following extraction from biological fluids. The compounds become intensely fluorescent in the presence of red, fuming nitric acid. The resulting compounds are quantitated with a spectrodensitometer with a fluorescent attachment. The sensitivity varies between 0.05 and 0.1 microgram. The coefficient of variation is 1.4% for assays in urine and 6.4% in serum.