超声测量健康成年哥伦比亚人群视神经鞘直径。

Ultrasound measurement of optic nerve sheath diameter in a healthy adult Colombian population.

机构信息

Department of Neurology, Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia.

Department of Critical Care Medicine, Fundación Cardioinfantil-Instituto de Cardiología, Bogotá, Colombia.

出版信息

BMC Neurol. 2023 Jan 13;23(1):16. doi: 10.1186/s12883-023-03062-4.

Abstract

BACKGROUND

Measurement of the optic nerve sheath diameter (ONSD) provides a rapid, safe, and easy method for detecting increased intracranial pressure (ICP). However, the normal mean and upper limit values may vary according to sex, age, ethnicity, and ultrasound technique.

AIM

We aimed to obtain the mean ONSD in a healthy Colombian adult population and to correlate it with demographic and anthropometric measures.

METHODS

In a prospective study using a 10-13 MHz linear ultrasound probe, eye transverse diameter (ETD) and ONSD in the transverse (ONSD-TP) and sagittal planes (ONSD-SP) were measured in healthy adult volunteers in Bogota, Colombia.

RESULTS

A total of 100 healthy subjects were included, with a mean age of 26,7 ± 8,3 years and 62 women. The mean ETD, ONSD-TP and ONSD-SP was 23.11 mm (95% confidence interval (CI): 22.90 mm-23.32 mm), 3.96 mm (95% CI: 3.85 mm-4.07 mm) and 4.0 mm (95% CI: 3.90 mm-4.11 mm), respectively. The ONSD in both planes ranged from 2.35 mm to 5.20 mm. There was a significant correlation between ONSD-SP and ONSD-TP (p < 0.0001) but no correlation between the ocular measures and demographic or anthropometric variables (p > 0.05). The intraclass correlation between the eyes was statistically significant.

CONCLUSION

Our study shows that ultrasound-measured ONSD in healthy adults in Colombia is similar to that found worldwide. An ONSD of 5.5 mm may be considered the upper limit for healthy adults in Colombia. ONSD can be measured in either plane; there is a good correlation between the two eyes; and ONSD is not modified by demographic or anthropometric characteristics.

摘要

背景

视神经鞘直径(ONSD)的测量为检测颅内压升高(ICP)提供了一种快速、安全、简便的方法。然而,正常均值和上限值可能因性别、年龄、种族和超声技术而异。

目的

我们旨在获得哥伦比亚健康成年人群的 ONSD 平均值,并将其与人口统计学和人体测量学指标相关联。

方法

在一项前瞻性研究中,使用 10-13MHz 线性超声探头,在哥伦比亚波哥大的健康成年志愿者中测量了眼横径(ETD)和横切(ONSD-TP)和矢状面(ONSD-SP)的 ONSD。

结果

共纳入 100 名健康受试者,平均年龄为 26.7±8.3 岁,其中 62 名为女性。平均 ETD、ONSD-TP 和 ONSD-SP 分别为 23.11mm(95%置信区间[CI]:22.90mm-23.32mm)、3.96mm(95%CI:3.85mm-4.07mm)和 4.0mm(95%CI:3.90mm-4.11mm)。两个平面的 ONSD 范围为 2.35mm 至 5.20mm。ONSD-SP 与 ONSD-TP 之间存在显著相关性(p<0.0001),但眼测量值与人口统计学或人体测量学变量之间无相关性(p>0.05)。双眼之间的组内相关具有统计学意义。

结论

我们的研究表明,哥伦比亚健康成年人的超声测量 ONSD 与全球范围内的结果相似。5.5mm 可能被认为是哥伦比亚健康成年人的上限。ONSD 可在任何一个平面上测量;双眼之间相关性良好;ONSD 不受人口统计学或人体测量学特征的影响。