Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil.
University of Anápolis, Anápolis, GO, Brazil.
Clin Oral Investig. 2023 Feb;27(2):433-474. doi: 10.1007/s00784-022-04797-z. Epub 2023 Jan 26.
OBJECTIVES: To evaluate the influence of image acquisition parameters (voxel, FOV, kVp, mA) on the accuracy of cone-beam computed tomography (CBCT) in detecting vertical root fracture (VRF). MATERIAL AND METHODS: Searches were performed in 6 main databases and the gray literature, without restrictions of language or date. Observational clinical studies (OCS) and in vitro-extracted teeth (IV) studies were considered eligible for inclusion when investigating the accuracy (sensitivity, specificity) of CBCT in detecting VRF in human teeth. The risk of bias was assessed using QUADAS-2, and a meta-analysis was performed using Review Manager v5.4 software and Jamovi software v1.6. RESULTS: A total of 60 out of 132 articles was included after fulfilling the eligibility criteria. Of these, 54 were IV studies while 6 were OCS. In the IV studies, it was seen that smaller FOV sizes tended to present higher accuracy values. The meta-analysis of the 6 OCS showed that the overall sensitivity and specificity values for 0.08 mm and 0.1 mm voxels were greater (0.84 and 0.79, respectively) than the sensitivity and specificity values for 0.125 mm and 0.2 mm voxels (0.70 and 0.55, respectively). CONCLUSIONS: Despite the uncertain risk of bias found for the IV and OCS studies, smaller voxel and FOV sizes seem to provide more accurate VRF detection values when using CBCT. CLINICAL RELEVANCE: This information is crucial for supporting the clinician when prescribing CBCT in cases of a clinical suspicion of VRF, and contributes to the personalization of the CBCT prescription, thereby ensuring greater accuracy in the VRF diagnosis. Registration This protocol was registered at the PROSPERO database (International Prospective Register of Systematic Review) under registration number CRD42020210118.
目的:评估图像采集参数(体素、视野、千伏、毫安)对锥形束计算机断层扫描(CBCT)检测垂直根折(VRF)准确性的影响。
材料与方法:在 6 个主要数据库和灰色文献中进行了检索,没有语言或日期限制。当研究 CBCT 在人类牙齿中检测 VRF 的准确性(灵敏度、特异性)时,观察性临床研究(OCS)和体外提取牙齿(IV)研究被认为符合纳入标准。使用 QUADAS-2 评估偏倚风险,并使用 Review Manager v5.4 软件和 Jamovi 软件 v1.6 进行荟萃分析。
结果:在满足入选标准后,共纳入 132 篇文章中的 60 篇。其中,54 篇为 IV 研究,6 篇为 OCS。在 IV 研究中,较小的视野尺寸往往呈现出更高的准确性值。6 项 OCS 的荟萃分析显示,0.08mm 和 0.1mm 体素的总体灵敏度和特异性值(分别为 0.84 和 0.79)高于 0.125mm 和 0.2mm 体素的灵敏度和特异性值(分别为 0.70 和 0.55)。
结论:尽管 IV 和 OCS 研究的偏倚风险不确定,但当使用 CBCT 时,较小的体素和视野尺寸似乎提供了更准确的 VRF 检测值。
临床相关性:当临床怀疑 VRF 时,临床医生开具 CBCT 时,这些信息非常重要,有助于个性化 CBCT 处方,从而确保 VRF 诊断的更高准确性。
注册:本方案在 PROSPERO 数据库(国际前瞻性系统评价注册库)中进行了注册,注册编号为 CRD42020210118。
Dentomaxillofac Radiol. 2017-12
Cochrane Database Syst Rev. 2022-5-20
Clin Cosmet Investig Dent. 2023-10-24