Mak Jonathan, Rens Neil, Savage Dasha, Nielsen-Bowles Helle, Triggs Doran, Talgo Julia, Gandhi Neil, Gutierrez Sebastian, Gutierrez Santiago, Aalami Oliver
Division of Vascular Surgery, Stanford University School of Medicine, 300 Pasteur Drive, Alway Bldg., M121, Stanford, CA, USA.
University of California, Berkeley, Berkeley, CA, USA.
Eur Heart J Digit Health. 2021 Feb 9;2(1):77-87. doi: 10.1093/ehjdh/ztab018. eCollection 2021 Mar.
The 6-min-walk test (6MWT) is a validated proxy for frailty and a predictor of clinical outcomes, yet is not widely used due to implementation challenges. This comparative effectiveness study assesses the reliability and repeatability of a home-based 6MWT compared to in-clinic 6MWTs in patients with cardiovascular disease.
One hundred and ten (110) patients scheduled for cardiac or vascular surgery were enrolled during a study period from June 2018 to December 2019 at the Palo Alto VA Hospital. Subjects were provided with an Apple iPhone 7 and Apple Watch Series 3 loaded with the VascTrac research study application and performed a supervised in-clinic 6MWT during enrolment, at 2 weeks, 1, 3, and 6 months post-operatively. Subjects also received notifications to perform at-home smartphone-based 6MWTs once a week for a duration of 6 months. Test-retest reliability of in-clinic measurements and at-home measurements was assessed with an industry standard Cronbach's alpha reliability test. Test-retest reliability for in-clinic ground truth 6MWT steps vs. in-clinic iPhone 6MWT steps was 0·99, showing high reliability between the two tested measurements. When comparing for in-clinic ground truth 6MWT steps vs. neighbouring at-home iPhone 6MWT steps, reliability was 0·74.
Running the test-reliability test on both measurements shows that an iPhone 6MWT test is reliable compared to an in-clinic ground truth measurement in patients with cardiovascular disease.
6分钟步行试验(6MWT)是一种经过验证的衰弱替代指标和临床结局预测指标,但由于实施方面的挑战,尚未得到广泛应用。这项比较有效性研究评估了在家中进行的6MWT与在诊所进行的6MWT相比,在心血管疾病患者中的可靠性和可重复性。
2018年6月至2019年12月期间,在帕洛阿尔托退伍军人医院招募了110名计划进行心脏或血管手术的患者。为受试者提供了一部装有VascTrac研究应用程序的苹果iPhone 7和苹果手表Series 3,并在入组时、术后2周、1个月、3个月和6个月进行了一次有监督的诊所内6MWT。受试者还收到通知,要求在6个月的时间内每周进行一次基于智能手机的家庭6MWT。使用行业标准的克朗巴赫α可靠性测试评估诊所测量和家庭测量的重测可靠性。诊所地面真值6MWT步数与诊所内iPhone 6MWT步数的重测可靠性为0.99,表明两次测试测量之间具有高度可靠性。当比较诊所地面真值6MWT步数与相邻的家庭iPhone 6MWT步数时,可靠性为0.74。
对两种测量方法进行测试可靠性测试表明,在心血管疾病患者中,iPhone 6MWT测试与诊所地面真值测量相比是可靠的。