Department of Cardiology, The First Affiliated Hospital of Soochow University, No.188 Shizi St, Suzhou, 215006, Jiangsu, China.
Department of Cardiology, The Third Affiliated Hospital of Soochow University, Changzhou, China.
J Interv Card Electrophysiol. 2023 Oct;66(7):1651-1658. doi: 10.1007/s10840-023-01473-4. Epub 2023 Feb 3.
The features of the unipolar electrogram (UEGM) and bipolar electrogram (BEGM) have been utilized to identify the site of origin of idiopathic premature ventricular contractions (PVCs) arising from pulmonary sinus cusps (PSCs), but for these PVCs, whether a negative concordance in the initial waves of both EGMs recorded above pulmonary valves can be used as a parameter to localize the origin has not been previously studied. We aimed to assess whether an initial negative concordance (INC) between the UEGM and BEGM might determine the origin of PVCs mapped and ablated within PSCs.
Data were collected from 22 patients undergoing successful radiofrequency catheter ablation for symptomatic idiopathic PVCs within PSCs. The morphological features of both the UEGM and the BEGM recorded at all ablation sites were analyzed.
A total of 109 sites within PSCs were ablated in 22 patients with an age (mean ± SD) of 47.2 ± 17.2 years. Ablation resulted in procedural success in all patients. The INC was observed at 18 of 22 (81.8%) successful ablation sites, contrasted with 3 of 87 (3.4%) unsuccessful sites (P < 0.001). The INC was consistent with the outcomes of conventional mapping parameters and proved to be an additional useful predictor of ablation success, with a sensitivity, specificity, positive predictive value and negative predictive value of 81.8%, 96.6%, 85.7% and 95.5%, respectively.
An INC between the UEGM and the BEGM can predict the origin of PVCs arising from PSCs. An initial negative concordance between unipolar and bipolar electrograms indicates that the distal electrode of the ablation catheter is at the origin of premature ventricular contractions within pulmonary sinus cusps.
单极电图(UEGM)和双极电图(BEGM)的特征已被用于识别起源于肺窦结(PSCs)的特发性室性期前收缩(PVCs)的起源部位,但对于这些 PVCs,尚未研究记录在肺瓣上方的两个 EGM 的初始波之间是否存在负性一致性是否可以用作定位起源的参数。我们旨在评估 UEGM 和 BEGM 之间的初始负性一致性(INC)是否可以确定在 PSCs 内标测和消融的 PVCs 的起源。
从 22 例因 PSCs 内症状性特发性 PVC 而行射频导管消融术成功的患者中收集数据。分析了在所有消融部位记录的 UEGM 和 BEGM 的形态特征。
22 例患者中有 109 个 PSCs 部位消融,年龄(均值±标准差)为 47.2±17.2 岁。所有患者均消融成功。在 22 个成功消融部位中的 18 个(81.8%)观察到 INC,而在 87 个不成功部位中的 3 个(3.4%)观察到 INC(P<0.001)。INC 与常规标测参数的结果一致,是消融成功的另一个有用预测指标,其敏感性、特异性、阳性预测值和阴性预测值分别为 81.8%、96.6%、85.7%和 95.5%。
UEGM 和 BEGM 之间的 INC 可以预测起源于 PSCs 的 PVCs 的起源。单极和双极电图之间的初始负性一致性表明消融导管的远端电极位于肺窦结内的室性期前收缩的起源处。