OBJECTIVE

Ankle arthrodesis (AA) is often fixed using cannulated screws. The irritation from metalwork is a relatively common complication, but there is no consensus regarding the need to remove the screws on a systematic basis. The aim of this study was to determine (1) the proportion of screws removed after AA and (2) whether predictors of screw removal could be identified.

METHODS

This PRISMA-compliant systematic review was part of a larger previous protocol registered on the PROSPERO platform. Multiple databases were searched including studies in which patients undergone AA using screws as exclusive fixation method were followed. Data were harvested regarding the cohort, the study design, the surgical technique, the nonunion and complication rate at the longest follow-up. Risk of bias was assessed using the modified Coleman Methodology Score (mCMS).

RESULTS

Forty-four series of patients from thirty-eight studies (1990 ankles, 1934 patients) were selected. The average follow-up was 40.8 months (range 12-110). In all studies, hardware was removed due to symptoms reported by patients and related to the screws. The pooled proportion of removal of metalwork was 3% (95% CI 2-4). The pooled proportion of fusion was 96% (95%CI 95-98), while the pooled proportion of complications and reoperations (excluding the removal of metalwork) stood at 15% (95% CI 11-18) and 3% (95% CI 2-4), respectively. The mean mCMS (50.8 ± 8.1, range 35-66) revealed only an overall fair quality of studies. The univariate analysis and the multivariate model showed that the year of publication (R = - 0.004; p = 0.01) and the number of screws (R = 0.08; p = 0.01) were associated with the screw removal rate. Specifically, we found that over time the removal rate decreased by 0.4% per year and that the use of three screws instead of two reduced the risk of removal of metalwork by 8%.

CONCLUSIONS

In this review, removal of metalwork after ankle arthrodesis using cannulated screws was needed in 3% of cases at an average follow-up of 40.8 months. It was indicated only in case of symptoms related to soft tissue irritation from screws. The use of three screws was paradoxically related to a reduced risk of removal of screws as compared to two-screw constructs.

LEVEL OF EVIDENCE

Level IV, systematic review of Level IV.

摘要

目的

踝关节融合术(AA)通常使用空心螺钉固定。金属部件的刺激是一种相对常见的并发症,但对于是否需要有系统地去除螺钉尚未达成共识。本研究旨在确定:(1)AA 后去除螺钉的比例;(2)是否可以确定去除螺钉的预测因素。

方法

本研究遵循 PRISMA 指南,是一项更大的先前方案的一部分,该方案已在 PROSPERO 平台上注册。我们检索了多个数据库,纳入了仅使用螺钉作为固定方法的 AA 患者的研究。收集的数据包括队列、研究设计、手术技术、最长随访时的非愈合率和并发症率。使用改良 Coleman 方法学评分(mCMS)评估偏倚风险。

结果

从 38 项研究中选取了 44 项患者系列(1990 个踝关节,1934 例患者)。平均随访时间为 40.8 个月(范围 12-110 个月)。在所有研究中,由于患者报告的与螺钉相关的症状而去除了内固定。金属部件的总体去除率为 3%(95%CI 2-4)。融合率的汇总比例为 96%(95%CI 95-98),而并发症和再次手术(不包括金属部件的去除)的比例分别为 15%(95%CI 11-18)和 3%(95%CI 2-4)。平均 mCMS(50.8±8.1,范围 35-66)仅显示研究的总体质量为中等。单变量分析和多变量模型表明,发表年份(R=-0.004;p=0.01)和螺钉数量(R=0.08;p=0.01)与螺钉去除率相关。具体而言,我们发现随着时间的推移,每年去除率降低 0.4%,而使用 3 个螺钉而不是 2 个螺钉可将金属部件去除的风险降低 8%。

结论

在本综述中,在平均 40.8 个月的随访中,使用空心螺钉进行踝关节融合术后,有 3%的病例需要去除金属部件。仅在与螺钉刺激软组织相关的症状需要时才去除。与使用 2 个螺钉的情况相比,使用 3 个螺钉反而会降低螺钉去除的风险。

证据等级

IV 级,IV 级系统评价。