耳鸣筛查器:短期测试-重测信度。

Tinnitus Screener: Short-Term Test-Retest Reliability.

机构信息

Veterans Affairs (VA) Rehabilitation Research & Development (RR&D) National Center for Rehabilitative Auditory Research (NCRAR), VA Portland Health Care System, OR.

OHSU-PSU School of Public Health, Oregon Health & Science University, Portland.

出版信息

Am J Audiol. 2023 Mar;32(1):232-242. doi: 10.1044/2022_AJA-22-00140. Epub 2023 Feb 17.

Abstract

PURPOSE

The Tinnitus Screener was introduced in 2015 as a four-item algorithmic instrument to assess the temporal characteristics of a person's reported tinnitus. The Tinnitus Screener was then revised as a six-item version to include a new temporal category and to capture tinnitus duration (acute < 6 months vs. chronic ≥ 6 months). When contrasted with audiologist assessment, the four-item Tinnitus Screener was determined to be highly valid, but the short-term reliability of either version remained unknown. The present analysis focused on determining the test-retest reliability of the six-item Tinnitus Screener. Additionally, we sought to determine whether reliability differed by respondent age, sex, military status, and hearing loss.

METHOD

The Tinnitus Screener was administered to 190 military Service members and 250 military Veterans at two time points separated by 7-31 days. Our analysis focused on test-retest reliability of responses as measured by the kappa coefficient, overall and within subsamples. Percent agreement of tinnitus categorization (temporal categories) and classification (positive/negative) between the two time points was also evaluated.

RESULTS

Constant or intermittent tinnitus was found in 31% of Service members and 53% of Veterans. Overall, kappa reliability coefficients were high, near .80, indicating substantial reliability. The majority (96%) of reliability coefficients for the Tinnitus Screener within subsamples were similarly high, ranging from .68 to .88.

CONCLUSIONS

The updated version of the Tinnitus Screener is shown to be a reliable instrument. The Tinnitus Screener is recommended to inform clinical decision making by determining the temporal characteristics of tinnitus.

摘要

目的

耳鸣筛查器于 2015 年作为一种四项算法工具推出,用于评估患者报告的耳鸣的时间特征。耳鸣筛查器随后被修订为六项版本,其中包括一个新的时间类别,并捕捉耳鸣持续时间(急性<6 个月与慢性≥6 个月)。与听力学家评估相比,四项耳鸣筛查器被确定具有高度的有效性,但两种版本的短期可靠性仍不清楚。本分析专注于确定六项耳鸣筛查器的测试-重测可靠性。此外,我们还试图确定可靠性是否因受访者年龄、性别、兵役状况和听力损失而不同。

方法

耳鸣筛查器在两个时间点(间隔 7-31 天)向 190 名现役军人和 250 名退役军人进行了测试。我们的分析主要集中在响应的测试-重测可靠性上,通过kappa 系数、总体和子样本进行测量。还评估了两个时间点之间耳鸣分类(时间类别)和分类(阳性/阴性)的百分比一致性。

结果

现役军人中有 31%,退役军人中有 53%的人存在持续或间歇性耳鸣。总体而言,kappa 可靠性系数很高,接近 0.80,表明可靠性很高。子样本中大多数(96%)耳鸣筛查器的可靠性系数也很高,范围从 0.68 到 0.88。

结论

更新后的耳鸣筛查器版本被证明是一种可靠的工具。推荐使用耳鸣筛查器来确定耳鸣的时间特征,从而为临床决策提供信息。