Suppr超能文献

陶瓷和不锈钢正畸附件上生物膜的厚度、活菌/死菌比例及矿物质含量的长期变化

Long-term changes in thickness, live/dead bacterial ratio, and mineral content in biofilm on ceramic and stainless steel orthodontic attachments.

作者信息

Krishnan Anjali, Rajendran Rahul, Damodaran Deepak, Manmadhan Sreelekshmi K, Krishnan Vinod

机构信息

Department of Orthodontics, Sri Sankara Dental College, Akathumuri, Varkala, Trivandrum, Kerala, India.

出版信息

J Orofac Orthop. 2023 Oct;84(Suppl 3):251-258. doi: 10.1007/s00056-023-00452-8. Epub 2023 Feb 23.

Abstract

PURPOSE

Fixed orthodontic appliances induce biofilm deposition, which harbors a microbial population harmful to the periodontal health of the individual. The present study evaluated the changes in thickness, live/dead bacterial ratio, and mineral content in dental biofilm over 6 months in patients with either stainless steel or ceramic orthodontic attachments.

METHODS

Eighty patients who require fixed orthodontic appliance treatment with first premolar extraction for correcting their malocclusion were selected and bonded with either stainless steel or ceramic orthodontic attachments on the buccal side. The attached buttons were retrieved at different periods-1 week, 1 month, 3 months, and 6 months. They were stained and visualized through confocal microscopy to detect biofilm thickness and the ratio of live/dead bacteria. X‑ray diffraction was used to identify the presence of calcium and phosphorous.

RESULTS

Ceramic attachments showed a greater increase in biofilm thickness in comparison to stainless steel attachments except in the initial 1‑week evaluation. A higher live/dead bacterial ratio was observed in stainless steel attachments than in their ceramic counterparts at all four evaluation periods. Both stainless steel and ceramic surfaces exhibited the presence of mineral deposition (calcium and phosphorous) at all periods.

CONCLUSIONS

More biofilm adhesion was observed over ceramic surfaces than over stainless steel orthodontic attachments. Stainless steel attachments exhibited biofilm with a higher live/dead bacterial ratio than their ceramic counterparts at all evaluation periods. The presence of calcium and phosphorous in the adhered biofilm, pointing toward its calcification process, was identified.

摘要

目的

固定正畸矫治器会诱导生物膜沉积,而生物膜中含有的微生物群体对个体的牙周健康有害。本研究评估了使用不锈钢或陶瓷正畸附件的患者在6个月内牙生物膜的厚度、活菌/死菌比例及矿物质含量的变化。

方法

选取80例需要通过拔除第一前磨牙进行固定正畸矫治以矫正错牙合畸形的患者,在其颊侧粘结不锈钢或陶瓷正畸附件。在不同时间段——1周、1个月、3个月和6个月——取下附着的按钮。对其进行染色并通过共聚焦显微镜观察,以检测生物膜厚度和活菌/死菌比例。采用X射线衍射法鉴定钙和磷的存在情况。

结果

与不锈钢附件相比,除最初1周的评估外,陶瓷附件的生物膜厚度增加更为明显。在所有四个评估时间段,不锈钢附件中的活菌/死菌比例均高于陶瓷附件。在所有时间段,不锈钢和陶瓷表面均有矿物质沉积(钙和磷)。

结论

与不锈钢正畸附件相比,陶瓷表面观察到更多的生物膜附着。在所有评估时间段,不锈钢附件中的生物膜活菌/死菌比例均高于陶瓷附件。已确定附着生物膜中存在钙和磷,表明其正在发生钙化过程。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验