Suppr超能文献

运用非侵入性的死后眼底照相评估婴儿猝死综合征中的视网膜出血。

Assessing retinal hemorrhages with non-invasive post-mortem fundus photographs in sudden unexpected death in infancy.

机构信息

Nantes Université, CHU Nantes, service d'ophtalmologie, Nantes, France.

CHU Grenoble, service de médecine légale, Grenoble, France.

出版信息

Int J Legal Med. 2023 May;137(3):913-923. doi: 10.1007/s00414-023-02964-9. Epub 2023 Feb 23.

Abstract

INTRODUCTION

In the case of sudden unexpected death in infancy (SUDI), eye examination is systematic to detect retinal hemorrhages (RH) that are a crucial hallmark for abusive head trauma (AHT). The aim of this study is to assess the ability of non-invasive post-mortem fundus photographs (PMFP) to detect RH in case of SUDI.

METHODS

Bicentric retrospective analysis of consecutive cases of SUDI under 2 years of age were managed by two French SUDI referral centers with PMFP by RetCam (Clarity Medical Systems USA). PMFP were reviewed randomly, twice, by three independent ophthalmologists blinded for clinical data.

RESULTS

Thirty cases (60 eyes) were included. Median age was 3.5 months (interquartile [1.6; 6.0]). No child died of AHT. Image quality was sufficient to assert presence or absence of RH in 50 eyes (83%). Sufficient quality rate was significantly higher when the post-mortem interval was inferior to 18 h (91%, 42/46) as opposed to over 18 h (57%, 8/14, p=0.0096). RH were found in six eyes (10%), four children (13%), with excellent inter and intra-raters' concordance (Cohen's Kappa from 0.81 [0.56-1.00] to 1.00 [1.00-1.00]).

CONCLUSION

PMFP can detect RH in case of SUDI and is a relevant systematic screening test to be carried out as soon as the deceased child arrives in the hospital. It can decrease the need of eye removal for pathological examination, but further studies are needed to define the best decision algorithm.

摘要

引言

在婴儿猝死综合征(SUDI)的情况下,眼部检查是系统的,以检测视网膜出血(RH),这是虐待性头部创伤(AHT)的关键标志。本研究旨在评估非侵入性死后眼底照片(PMFP)在 SUDI 情况下检测 RH 的能力。

方法

对两家法国 SUDI 转诊中心连续收治的 2 岁以下 SUDI 连续病例进行了双中心回顾性分析,采用 RetCam(美国 Clarity Medical Systems)进行 PMFP。PMFP 由三名独立的眼科医生随机审查两次,这些医生对临床数据进行了盲法评估。

结果

共纳入 30 例(60 只眼)。中位年龄为 3.5 个月(四分位距 [1.6; 6.0])。没有儿童死于 AHT。在 50 只眼中(83%),图像质量足以确定 RH 的存在或不存在。当死后间隔小于 18 小时时(91%,42/46),足够的质量率明显高于超过 18 小时(57%,8/14,p=0.0096)。在 6 只眼睛(10%)、4 名儿童(13%)中发现了 RH,观察者间和观察者内的一致性非常好(Cohen 的 Kappa 从 0.81 [0.56-1.00]到 1.00 [1.00-1.00])。

结论

PMFP 可在 SUDI 情况下检测到 RH,是一种相关的系统筛查试验,应在死亡儿童到达医院后尽快进行。它可以减少对病理性检查的眼球摘除的需求,但需要进一步的研究来确定最佳决策算法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1ab2/10085933/3a2031ed1b91/414_2023_2964_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验