Abstract

Rapid immunochemical assays were developed for the determination of apolipoproteins A-1 and B in serum. The methods are based on the measurement of immunoprecipitation at a wavelength of 340 nm. Both assays are easy to perform, their reproducibilities are good (the coefficients of variation for within-run and between-run imprecisions are below 5%), and their correlations with radial immunodiffusion method are high (r = 0.96). The effect of storage on native serum specimens was also studied. Apolipoprotein B is stable at least 4 weeks in a refrigerator but in some specimens the level of apolipoprotein A-1 rises nearly 10% during this time. Repeated freezing and thawing, on the other hand, may have a harmful effect, especially on apolipoprotein B. Therefore, use of fresh serum specimens is recommended for both assays. The present method is well suited for routine measurements because it can be easily adapted to most clinical chemistry analysers.

摘要

已开发出快速免疫化学分析法用于测定血清中的载脂蛋白A-1和B。这些方法基于在340nm波长处对免疫沉淀的测量。两种分析方法操作简便,重复性良好(批内和批间不精密度的变异系数均低于5%),且与放射免疫扩散法的相关性很高(r = 0.96)。还研究了储存对天然血清标本的影响。载脂蛋白B在冰箱中至少4周稳定,但在某些标本中,在此期间载脂蛋白A-1水平会升高近10%。另一方面,反复冻融可能有有害影响,尤其是对载脂蛋白B。因此,两种分析均建议使用新鲜血清标本。本方法非常适合常规测量,因为它可轻松适配大多数临床化学分析仪。