Suppr超能文献

双侧经颅直流电刺激可能是治疗帕金森震颤的一种可行方法。

Bilateral transcranial direct current stimulation may be a feasible treatment of Parkinsonian tremor.

作者信息

Zhang Bin, Huang Feifei, Liu Jun, Zhang Dingguo

机构信息

State Key Laboratory of Mechanical Systems and Vibrations, Robotics Institute, Shanghai Jiao Tong University, Shanghai, China.

Department of Neurology, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.

出版信息

Front Neurosci. 2023 Feb 24;17:1101751. doi: 10.3389/fnins.2023.1101751. eCollection 2023.

Abstract

BACKGROUND

Parkinsonian tremor is a common pathological tremor that affects over 6 million people worldwide. It lowers patients' quality of life and threatens their career development, especially when patients' occupation requires dexterous manipulation. In spite of current available treatments in clinics, there is a lack of low-cost, low side-effect, effective solutions for Parkinsonian tremor. Transcranial direct current stimulation (tDCS) may be an alternative treatment.

OBJECTIVE

In this research, we explored the immediate effect of tDCS with a novel bilateral electrode setup over Parkinsonian tremor. In such a bilateral setup, the cathode was placed over the primary cortex contralateral to the more affected side of Parkinsonian tremor while the anode symmetrically over the other hemisphere. It was designed as a modification to the traditional cathodal setup. The performance of this bilateral setup was compared with three other setups including anodal setup, cathodal setup, and sham (control).

METHODS

A randomized, sham-controlled, double-blind, crossover experiment was carried out over 13 qualified patients diagnosed with idiopathic Parkinson's disease (PD). Before and after the stimulus of each tDCS setup, subjects were tested before and after tDCS with four measures, including the Unified Parkinson's Disease Rating Scale (UPDRS), Fahn-Tolosa-Marin Tremor Rating Scale (FTMTRS), Purdue Pegboard Test (PPT) and a self-design Continuous Tremor Signal Assessment (CTSA). Tremor intensity calculated from CTSA data were regarded as the primary outcome of the experiment.

RESULTS

Statistical results of CTSA, FTMTRS and PPT showed both bilateral tDCS and cathodal tDCS effectively suppressed Parkinsonian tremor. A quantitative comparison of the effect in tremor suppression indicated the optimal suppressive effect was obtained with bilateral tDCS. Based on the results of UPDRS, anodal tDCS was found to benefit subjects' overall performance the most, however, it had little effect in improving Parkinsonian tremor, as revealed by the results of other evaluations.

CONCLUSION

Our study suggests a beneficial immediate effect of bilateral tDCS in Parkinsonian tremor suppression. In addition, we assume there may be an underlying interhemispheric unbalance of cortical excitability which contributes to Parkinsonian tremor genesis.

CLINICAL TRIAL REGISTRATION

Identifier: ChiCTR2100054804.

摘要

背景

帕金森震颤是一种常见的病理性震颤,全球有超过600万人受其影响。它降低了患者的生活质量,威胁着他们的职业发展,尤其是当患者的职业需要灵巧操作时。尽管临床上有现有的治疗方法,但对于帕金森震颤仍缺乏低成本、低副作用且有效的解决方案。经颅直流电刺激(tDCS)可能是一种替代治疗方法。

目的

在本研究中,我们探索了采用新型双侧电极设置的tDCS对帕金森震颤的即时效应。在这种双侧设置中,阴极置于帕金森震颤较严重一侧对侧的初级皮层上,而阳极对称地置于另一侧半球上。它被设计为对传统阴极设置的一种改进。将这种双侧设置的性能与其他三种设置进行比较,包括阳极设置、阴极设置和假刺激(对照)。

方法

对13名被诊断为特发性帕金森病(PD)的合格患者进行了一项随机、假刺激对照、双盲、交叉实验。在每种tDCS设置刺激前后,对受试者进行四次测量,包括统一帕金森病评定量表(UPDRS)、法恩 - 托洛萨 - 马林震颤评定量表(FTMTRS)、普渡钉板试验(PPT)和自行设计的连续震颤信号评估(CTSA)。从CTSA数据计算出的震颤强度被视为实验的主要结果。

结果

CTSA、FTMTRS和PPT的统计结果表明,双侧tDCS和阴极tDCS均能有效抑制帕金森震颤。对震颤抑制效果的定量比较表明,双侧tDCS获得了最佳抑制效果。基于UPDRS的结果,发现阳极tDCS对受试者的整体表现益处最大,然而,正如其他评估结果所示,它在改善帕金森震颤方面作用不大。

结论

我们的研究表明双侧tDCS在抑制帕金森震颤方面具有有益的即时效应。此外,我们假设可能存在潜在的半球间皮质兴奋性失衡,这导致了帕金森震颤的发生。

临床试验注册

标识符:ChiCTR2100054804。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4ed8/9998710/2a1d1c1337f9/fnins-17-1101751-g0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验