Suppr超能文献

光学相干断层扫描血管造影术评估血管密度和通量的定量分析及可重复性

Quantification and Repeatability of Vessel Density and Flux as Assessed by Optical Coherence Tomography Angiography.

作者信息

Pappelis Konstantinos, Jansonius Nomdo M

机构信息

Department of Ophthalmology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.

Graduate School of Medical Sciences (Research School of Behavioural and Cognitive Neurosciences), University of Groningen, Groningen, The Netherlands.

出版信息

Transl Vis Sci Technol. 2019 May 2;8(3):3. doi: 10.1167/tvst.8.3.3. eCollection 2019 May.

Abstract

PURPOSE

To determine the intrasession repeatability (test-retest variability) of parafoveal and peripapillary perfused capillary density (PCD) and normalized flux index (NFI) as assessed with Canon OCT-HS100 angiography.

METHODS

Pairs of optical coherence tomography angiography (OCT-A) images were obtained from the parafoveal and peripapillary region of 30 eyes of 30 healthy subjects. PCD and NFI were calculated using generic image-processing software. Macular ganglion-cell complex thickness (GCC) and peripapillary retinal nerve fiber layer thickness (RNFLT) were also recorded. Bland-Altman analysis was performed and the coefficient of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated. Correlations of parafoveal PCD/NFI with GCC and of peripapillary PCD/NFI with RNFLT were also computed.

RESULTS

Mean (standard deviation) parafoveal and peripapillary PCD were 40.0% (1.8%) and 44.5% (1.3%), respectively. Corresponding values for NFI were 151.2 (6.8) and 164.2 (3.9). For PCD, ICC was 0.76 for parafoveal and 0.79 for peripapillary measurements; corresponding CoRs were 2.7% and 1.8%. Corresponding values for NFI were 0.62 and 0.67 for ICC and 13.3 and 7.0 for CoR. Average measures ICC was 0.87/0.88 and 0.76/0.80 for the parafoveal/peripapillary PCD and NFI, respectively. PCD and NFI were weakly correlated with GCC ( = 0.39, = 0.035; = 0.33, = 0.077) and moderately correlated with RNFLT ( = 0.43, = 0.017; = 0.55, = 0.002).

CONCLUSIONS

Repeatability of a commercially available OCT-A with generic image-processing software was good (NFI) to excellent (PCD). Our results indicate that changes surpassing the variability in healthy subjects should be easily detectable in a clinical setting.

TRANSLATIONAL RELEVANCE

Repeatability estimates provide information regarding the relevance of changes in retinal perfusion.

摘要

目的

使用佳能 OCT-HS100 血管造影评估黄斑旁和视乳头周围灌注毛细血管密度(PCD)及标准化血流指数(NFI)的日内重复性(重测变异性)。

方法

从 30 名健康受试者的 30 只眼中获取黄斑旁和视乳头周围区域的光学相干断层扫描血管造影(OCT-A)图像对。使用通用图像处理软件计算 PCD 和 NFI。还记录黄斑神经节细胞复合体厚度(GCC)和视乳头周围视网膜神经纤维层厚度(RNFLT)。进行 Bland-Altman 分析并计算重复性系数(CoR)和组内相关系数(ICC)。还计算黄斑旁 PCD/NFI 与 GCC 以及视乳头周围 PCD/NFI 与 RNFLT 的相关性。

结果

黄斑旁和视乳头周围 PCD 的平均值(标准差)分别为 40.0%(1.8%)和 44.5%(1.3%)。NFI 的相应值为 151.2(6.8)和 164.2(3.9)。对于 PCD,黄斑旁测量的 ICC 为 0.76,视乳头周围测量的 ICC 为 0.79;相应的 CoR 分别为 2.7%和 1.8%。NFI 的相应 ICC 值为 0.62 和 0.67,CoR 值为 13.3 和 7.0。黄斑旁/视乳头周围 PCD 和 NFI 的平均测量 ICC 分别为 0.87/0.88 和 0.76/0.80。PCD 和 NFI 与 GCC 弱相关(r = 0.39,P = 0.035;r = 0.33,P = 0.077),与 RNFLT 中度相关(r = 0.43,P = 0.017;r = 0.55,P = 0.002)。

结论

使用通用图像处理软件的商用 OCT-A 的重复性良好(NFI)至优秀(PCD)。我们的结果表明,在临床环境中应易于检测到超过健康受试者变异性的变化。

转化相关性

重复性估计提供了有关视网膜灌注变化相关性的信息。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7ad2/6502070/4b448357ddac/i2164-2591-8-3-3-f01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验