Suppr超能文献

无额外标记物的无牙颌口腔内扫描:口腔内扫描与锥形束计算机断层扫描在扫描精度和配准方面的验证研究。

Intraoral scanning of the edentulous jaw without additional markers: An validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan.

作者信息

Deferm Julie Tilly, Baan Frank, Nijsink Johan, Verhamme Luc, Maal Thomas, Meijer Gert

机构信息

Department of Oral and Maxillofacial Surgery, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands.

3D Laboratory, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands.

出版信息

Imaging Sci Dent. 2023 Mar;53(1):21-26. doi: 10.5624/isd.20220131. Epub 2023 Feb 1.

Abstract

PURPOSE

A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw.

MATERIALS AND METHODS

Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient (ICC) was calculated to evaluate the reproducibility of the registration method.

RESULTS

The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10 ± 0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent (ICC=0.94; 95% confidence interval, 0.81-0.98).

CONCLUSION

Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

摘要

目的

口腔修复的全数字化方法需要能够整合(即记录)来自不同来源的数字文档。在无牙颌中,这变得更加复杂,因为缺乏用于进行可靠记录的固定牙科标记。本验证研究旨在评估1)口腔内扫描以及2)使用锥形束计算机断层扫描(CBCT)对上颌全口无牙颌进行口腔内扫描的软组织基础记录的可重复性。

材料与方法

两名观察者独立对14名全口无牙颌患者的上颌进行口腔内扫描。将两个表面模型的腭穹窿对齐,并通过计算牙槽嵴水平处的平均表面间距离来评估观察者间的变异性。此外,对所有患者进行CBCT扫描,并使用患者特定的灰度值生成软组织表面模型。将该CBCT软组织模型与两名观察者的口腔内扫描进行配准,并计算组内相关系数(ICC)以评估配准方法的可重复性。

结果

对上颌全口无牙颌进行口腔内扫描时,观察者间的平均偏差为0.10±0.09mm。基于软组织的配准方法的观察者间一致性极佳(ICC=0.94;95%置信区间,0.81-0.98)。

结论

即使没有牙齿,对上颌进行口腔内扫描以及使用CBCT扫描对口腔内扫描进行基于软组织的配准也可以高精度地进行。