Gupta Sheetal, Hishikar Prayank, Sharma Anmol
Galaxy Hospital, Bhopal, India.
Arthrosc Tech. 2023 Feb 8;12(3):e313-e320. doi: 10.1016/j.eats.2022.11.009. eCollection 2023 Mar.
Arthroscopic posterior cruciate ligament (PCL) reconstruction is a technically demanding procedure and is associated with several intraoperative and postoperative complications, although less-common but intraoperative iatrogenic popliteal artery injuries have been reported. At our center, we developed a simple and effective technique using a Foley balloon catheter that ensures a safe surgery to avoid possible neurovascular complications. Through a lower posteromedial portal, this inflated balloon acts as protective mechanism between the PCL and posterior capsule. Betadine or methylene blue dye is used to inflate this bulb, which provides easy identification if balloon ruptures, as evidenced by leakage of this solution in posterior compartment. This balloon increases significant distance, equivalent to the diameter of the balloon, between the PCL and popliteal artery by pushing the capsule more posteriorly. This balloon catheter protection technique combined with other methods will ensure a greater level of safety when performing an anatomical PCL reconstruction.
关节镜下后交叉韧带(PCL)重建是一项技术要求较高的手术,且与多种术中及术后并发症相关,尽管医源性腘动脉损伤较少见,但已有术中相关报道。在我们中心,我们开发了一种使用Foley球囊导管的简单有效技术,可确保手术安全,避免可能的神经血管并发症。通过较低的后内侧入路,这个充气的球囊在PCL和后关节囊之间起到保护作用。用碘伏或亚甲蓝染料给球囊充气,如果球囊破裂,该溶液会在后侧间隙漏出,便于识别。这个球囊通过将关节囊进一步向后推,在PCL和腘动脉之间增加了相当于球囊直径的显著距离。这种球囊导管保护技术与其他方法相结合,将在进行解剖学PCL重建时确保更高的安全性。