正常与亚临床圆锥角膜视网膜图像质量的差异及其与角膜后表面不对称的关联。

Differences in retinal images quality between normal and subclinical keratoconus and its association to posterior corneal asymmetry.

作者信息

Smadja David, Krauthammer Mark, Wajnsztajn Denise, Abulafia Adi, Zadok David, Lavy Itay

机构信息

Department of Ophthalmology, Hadassah Medical Center, Jerusalem, Israel.

Ein Tal Hadassah Laser Institute, Tel Aviv, Israel.

出版信息

Eur J Ophthalmol. 2023 Jul;33(4):1567-1575. doi: 10.1177/11206721231166559. Epub 2023 Apr 3.

Abstract

PURPOSE

To compare retinal image quality in subclinical keratoconus and normal eyes using a double-pass aberrometer and to correlate it with posterior surface deformation.

METHODS

Sixty normal corneas were compared to 20 subclinical keratoconus (SKC) corneas. Retinal image quality was assessed using a double-pass system in all the eyes. The objective scatter index (OSI) modulation transfer function (MTF) cutoff, Strehl ratio (SR), and Predicted Visual Acuity (PVA) values at 100%, 20%, and 9% were calculated and compared between the groups. Posterior corneal asymmetry was measured using a combined Placido Dual Scheimpflug Analyzer, and correlations were tested with all optical quality parameters.

RESULTS

Significant decrease in optical quality parameters was observed in SKC eyes compared with that in normal eyes. Subclinical KC eyes expressed greater scattering (OSI = 0.66 ± 0.36 vs 0.47 ± 0.26) and reduced contrast images (MTF and SR) than normal eyes, with 38.82 ± 9.4 and 0.22 ± 0.04, and 44.35 ± 7.1 and 0.24 ± 0.04, respectively. The reduction in the image contrast parameters (MTF and SR) was strongly correlated to the level of posterior corneal asymmetry in SKC. The greater the posterior asymmetry, the more affected was the image contrast, with r = -0.63 and -0.59, respectively for MTF and SR.

CONCLUSION

Retinal image quality was significantly more affected in eyes with subclinical keratoconus than in normal eyes. The reduction in optical quality observed in subclinical keratoconus was strongly associated with the increased asymmetry of the posterior cornea.

摘要

目的

使用双程像差仪比较亚临床圆锥角膜和正常眼睛的视网膜图像质量,并将其与后表面变形相关联。

方法

将60只正常角膜与20只亚临床圆锥角膜(SKC)角膜进行比较。在所有眼睛中使用双程系统评估视网膜图像质量。计算并比较两组在100%、20%和9%时的客观散射指数(OSI)、调制传递函数(MTF)截止值、斯特列尔比(SR)和预测视力(PVA)值。使用组合式普拉西多双施密夫鲁格分析仪测量角膜后表面不对称性,并测试其与所有光学质量参数的相关性。

结果

与正常眼睛相比,SKC眼睛的光学质量参数显著降低。亚临床圆锥角膜眼睛比正常眼睛表现出更大的散射(OSI = 0.66±0.36对0.47±0.26)和对比度降低的图像(MTF和SR),分别为38.82±9.4和0.22±0.04,以及44.35±7.1和0.24±0.04。图像对比度参数(MTF和SR)的降低与SKC角膜后表面不对称程度密切相关。后表面不对称性越大,图像对比度受影响越大,MTF和SR的r值分别为-0.63和-0.59。

结论

亚临床圆锥角膜眼睛的视网膜图像质量受影响程度明显高于正常眼睛。亚临床圆锥角膜中观察到的光学质量下降与角膜后表面不对称性增加密切相关。