Suppr超能文献

正常和亚临床圆锥角膜眼中的角膜生物力学。

Corneal biomechanics in normal and subclinical keratoconus eyes.

机构信息

Isfahan Eye Research Center, Department of Ophthalmology, Isfahan University of Medical Sciences, Isfahan, Iran.

School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.

出版信息

BMC Ophthalmol. 2023 Nov 15;23(1):459. doi: 10.1186/s12886-023-03215-6.

Abstract

BACKGROUND

The diagnosis of keratoconus, as the most prevalent corneal ectatic disorder, at the subclinical stage gained great attention due to the increased acceptance of refractive surgeries. This study aimed to assess the pattern of the corneal biomechanical properties derived from Corneal Visualization Scheimpflug Technology (Corvis ST) and evaluate the diagnostic value of these parameters in distinguishing subclinical keratoconus (SKC) from normal eyes.

METHODS

This prospective study was conducted on 73 SKC and 69 normal eyes. Subclinical keratoconus eyes were defined as corneas with no clinical evidence of keratoconus and suspicious topographic and tomographic features. Following a complete ophthalmic examination, topographic and tomographic corneal assessment via Pentacam HR, and corneal biomechanical evaluation utilizing Corvis ST were done.

RESULTS

Subclinical keratoconus eyes presented significantly higher Deformation Amplitude (DA) ratio, Tomographic Biomechanical Index (TBI), and Corvis Biomechanical Index (CBI) rates than the control group. Conversely, Ambrósio Relational Thickness to the Horizontal profile (ARTh), and Stiffness Parameter at the first Applanation (SPA1) showed significantly lower rates in SKC eyes. In diagnosing SKC from normal eyes, TBI (AUC: 0.858, Cut-off value: > 0.33, Youden index: 0.55), ARTh (AUC: 0.813, Cut-off value: ≤ 488.1, Youden index: 0.58), and CBI (AUC: 0.804, Cut-off value: > 0.47, Youden index: 0.49) appeared as good indicators.

CONCLUSIONS

TBI, CBI, and ARTh parameters could be valuable in distinguishing SKC eyes from normal ones.

摘要

背景

作为最常见的角膜扩张性疾病,圆锥角膜在亚临床阶段的诊断引起了广泛关注,这主要是由于屈光手术的接受度增加所致。本研究旨在评估基于角膜可视化Scheimpflug 技术(Corvis ST)得出的角膜生物力学特性模式,并评估这些参数在区分亚临床圆锥角膜(SKC)与正常眼方面的诊断价值。

方法

本前瞻性研究纳入了 73 例 SKC 眼和 69 例正常眼。亚临床圆锥角膜眼定义为无临床证据的圆锥角膜和可疑的地形图和断层图特征的角膜。在进行全面眼科检查后,使用 Pentacam HR 进行地形图和断层评估,以及使用 Corvis ST 进行角膜生物力学评估。

结果

亚临床圆锥角膜眼的变形幅度(DA)比、断层生物力学指数(TBI)和角膜生物力学指数(CBI)比率显著高于对照组。相反,在 SKC 眼中,水平剖面的 Ambrósio 相关厚度(ARTh)和第一次压平的刚性参数(SPA1)显著较低。在将 SKC 与正常眼区分开来时,TBI(AUC:0.858,临界值:>0.33,Youden 指数:0.55)、ARTh(AUC:0.813,临界值:≤488.1,Youden 指数:0.58)和 CBI(AUC:0.804,临界值:>0.47,Youden 指数:0.49)表现为良好的指标。

结论

TBI、CBI 和 ARTh 参数可用于区分 SKC 眼与正常眼。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/dc7e/10647094/ceb801c4613c/12886_2023_3215_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验