Suppr超能文献

胰腺 CT 脂肪分数全容积自动测量:与 Dixon MR 成像的相关性。

Automated whole-volume measurement of CT fat fraction of the pancreas: correlation with Dixon MR imaging.

机构信息

Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Yamaguchi, Japan.

出版信息

Br J Radiol. 2023 Jun 1;96(1146):20220937. doi: 10.1259/bjr.20220937. Epub 2023 Apr 22.

Abstract

OBJECTIVES

This study aimed to assess the feasibility of pancreatic steatosis quantification by automated whole-volume measurement of the fat fraction of the pancreas on CT in comparison to MRI using proton-density fat fraction (PDFF) techniques.

METHODS

Fifty-nine patients who underwent both CT and MRI were analyzed. Automated whole-volume measurement of pancreatic fat on unenhanced CT was performed by a histogram analysis with local thresholding. Three sets of CT fat volume fraction (FVF) (%) values with thresholds of -30 Hounsfield unit (HU), -20 HU and -10 HU were compared to MR-FVF (%) values measured on a PDFF map.

RESULTS

The median -30 HU CT-FVF, -20 HU CT-FVF, -10 HU CT-FVF and MR-FVF values of the pancreas were 8.6% (interquartile range (IQR), 11.3), 10.5% (IQR, 13.2), 13.4% (IQR, 16.1) and 10.9% (IQR, 9.7), respectively. The -30 HU CT-FVF (%), -20 HU CT-FVF (%) and -10 HU CT-FVF (%) of the pancreas showed a significant positive correlation with the MR-FVF (%) of the pancreas ( = 0.898, < 0.001, = 0.905, < 0.001, = 0.909, < 0.001, respectively). The -20 HU CT-FVF (%) displayed reasonable agreement with the MR-FVF (%) with a low absolute fixed bias (mean difference, 0.32%; limit of agreement from -10.1 to 10.7%).

CONCLUSION

The automated whole-volume measurement of the CT fat fraction of the pancreas using the threshold CT attenuation value of -20 HU may be a feasible, non-invasive, and convenient technique for quantifying pancreatic steatosis.

ADVANCES IN KNOWLEDGE

CT-FVF value of the pancreas had a positive correlation with the MR-FVF value. The -20 HU CT-FVF may be a convenient technique for quantifying pancreatic steatosis.

摘要

目的

本研究旨在评估 CT 胰腺脂肪分数全自动全容积测量与 MRI 质子密度脂肪分数 (PDFF) 技术相比评估胰腺脂肪变性的可行性。

方法

对 59 例行 CT 和 MRI 检查的患者进行分析。在未增强 CT 上通过局部阈值直方图分析对胰腺脂肪进行全自动全容积测量。将三组胰腺脂肪体积分数 (FVF) (%) 值(阈值为 -30HU、-20HU 和-10HU)与 PDFF 图谱上测量的 MR-FVF(%) 值进行比较。

结果

胰腺的中位 -30HU CT-FVF、-20HU CT-FVF、-10HU CT-FVF 和 MR-FVF 值分别为 8.6%(四分位距 (IQR),11.3)、10.5%(IQR,13.2)、13.4%(IQR,16.1)和 10.9%(IQR,9.7)。胰腺的-30HU CT-FVF(%)、-20HU CT-FVF(%)和-10HU CT-FVF(%)与胰腺的 MR-FVF(%)呈显著正相关( = 0.898,<0.001, = 0.905,<0.001, = 0.909,<0.001,分别)。-20HU CT-FVF(%)与 MR-FVF(%)显示出合理的一致性,且具有较低的绝对固定偏差(平均差值,0.32%;一致性范围为 -10.1 至 10.7%)。

结论

使用 -20HU 衰减值的 CT 胰腺脂肪分数全自动全容积测量可能是一种可行的、非侵入性的、方便的胰腺脂肪变性定量技术。

知识进展

胰腺 CT-FVF 值与 MR-FVF 值呈正相关。-20HU CT-FVF 可能是一种方便的胰腺脂肪变性定量技术。

相似文献

本文引用的文献

7
Nonalcoholic Fatty Pancreas Disease.非酒精性脂肪性胰腺病。
Nutr Clin Pract. 2019 Oct;34 Suppl 1:S49-S56. doi: 10.1002/ncp.10397.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验