District Hospital of Orthopaedics and Trauma Surgery in Piekary Śląskie. Bytomska, St. 62, 41-940, Piekary Śląskie, Poland.
Department of Biochemistry, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, Jordana St. 19, 41-808, Zabrze, Poland.
Eur J Orthop Surg Traumatol. 2023 Oct;33(7):3089-3097. doi: 10.1007/s00590-023-03540-y. Epub 2023 Apr 5.
Growing number of hip arthroplasty in Poland performed with the use of metaphyseal stems results from the decreasing age of patients qualified for procedures and is consistent with the corresponding trends in European countries. To this day, a significant population functions after undergoing hip replacement using metal-on-metal implant. This study was aimed at the assessment of the variability of the oxidative system, as well as the concentrations of chromium and cobalt ions in serum and blood and their potential impact on postoperative clinical status.
The analysis included 58 men. The first group-operated using J&J DePuy ASR metal-on-metal implant with metaphyseal stem Proxima. Second group-operated using K-Implant SPIRON® femoral neck prosthesis in full ceramic articulation. Selected parameters of oxidative stress and the antioxidant system as well as the concentration of metal ions in blood were determined twice. Each patient underwent two clinical evaluations using acclaimed physical examination scale systems.
In the first group, significantly higher concentrations of Cr (p = 0.028) and Co (p = 0.002) were demonstrated compared to the group of femoral neck arthroplasty. The mean concentrations of Cr and Co, 10.45 and 9.26 μg/l, respectively, were higher in patients operated bilaterally. In the ASR group, greater pain intensity in the operated hip and higher indicators of oxidative stress were found.
Metal-on-metal articulation of the hip significantly increases the concentration of Cr and Co in blood, induces oxidative stress and modifies function of the antioxidant system and generates greater pain in the operated hip.
波兰越来越多的髋关节置换术采用干骺端柄进行,这与接受手术患者的年龄不断下降有关,与欧洲国家的相应趋势一致。时至今日,大量人群在接受金属对金属植入物的髋关节置换术后仍能正常生活。本研究旨在评估氧化系统的可变性,以及血清和血液中铬和钴离子的浓度及其对术后临床状况的潜在影响。
分析纳入了 58 名男性。第一组采用强生公司的 DePuy ASR 金属对金属植入物与干骺端柄 Proxima 进行手术。第二组采用 K-Implant SPIRON®股骨颈全陶瓷关节假体进行手术。两次测定了氧化应激和抗氧化系统的选定参数以及血液中金属离子的浓度。每位患者均采用两种广受认可的体格检查量表系统进行两次临床评估。
与股骨颈置换组相比,第一组的 Cr(p=0.028)和 Co(p=0.002)浓度明显升高。Cr 和 Co 的平均浓度分别为 10.45μg/l 和 9.26μg/l,双侧手术患者的浓度更高。在 ASR 组中,手术髋关节的疼痛强度更大,氧化应激的指标也更高。
髋关节的金属对金属关节会显著增加血液中 Cr 和 Co 的浓度,诱导氧化应激,改变抗氧化系统的功能,并增加手术髋关节的疼痛。