Laboratory of Immunology and Allergology, S. Giovanni di Dio Hospital, Florence, Italy.
Department of Clinical and Experimental Medicine, University of Florence, Florence, Italy.
Clin Chem Lab Med. 2023 Apr 7;61(9):1619-1622. doi: 10.1515/cclm-2023-0109. Print 2023 Aug 28.
Rheumatoid arthritis (RA) is a systemic autoimmune disease characterised by the presence of autoantibodies that are used for classification of the disease. Though routine diagnostics is commonly restricted to measuring rheumatoid factor (RF) and anti-citrullinated protein antibodies, detection of RF IgM, IgG and IgA isotypes, may increase the power of RA serodiagnosis by reducing the number of seronegative patients as well as provide prognostic information. The agglutination-based RF assays, such as nephelometry or turbidimetry, are unable to differentiate isotypes. We compared three different immunoassays used in current laboratory practice to detect RF isotypes.
We tested 117 consecutive serum samples that were positive for total RF at nephelometry, from 55 RA and 62 non-RA subjects. IgA, IgG, and IgM isotypes of RF were tested by immunoenzymatic (ELISA, Technogenetics), fluoroenzymatic (FEIA, ThermoFisher) and chemiluminescence (CLIA, YHLO Biotech Co.) immunoassays.
Diagnostic performance differed considerably between the assays, especially with regard to RF IgG isotype. Agreement among methods by Cohen's kappa ranged from 0.05 (RF IgG CLIA vs. FEIA) to 0.846 (RF IgM CLIA vs. FEIA).
The poor agreement observed in this study indicates substantial lack of comparability among assays for RF isotypes. Harmonization of these tests requires further efforts before their measurement can be used in clinical practice.
类风湿关节炎(RA)是一种系统性自身免疫性疾病,其特征是存在用于疾病分类的自身抗体。尽管常规诊断通常仅限于测量类风湿因子(RF)和抗瓜氨酸蛋白抗体,但检测 RF IgM、IgG 和 IgA 同种型可能会通过减少血清阴性患者的数量并提供预后信息,从而提高 RA 血清诊断的效力。基于凝集的 RF 检测方法,如散射比浊法或速率浊度法,无法区分同种型。我们比较了目前实验室实践中使用的三种不同的免疫测定法来检测 RF 同种型。
我们测试了 117 份连续的血清样本,这些样本在散射比浊法中总 RF 呈阳性,来自 55 名 RA 和 62 名非 RA 患者。RF 的 IgA、IgG 和 IgM 同种型通过免疫酶(ELISA,Technogenetics)、荧光酶(FEIA,ThermoFisher)和化学发光(CLIA,YHLO Biotech Co.)免疫测定法进行测试。
不同检测方法的诊断性能差异很大,尤其是在 RF IgG 同种型方面。Cohen's kappa 之间的方法一致性范围从 0.05(RF IgG CLIA 与 FEIA)到 0.846(RF IgM CLIA 与 FEIA)。
本研究中观察到的一致性差表明 RF 同种型检测之间存在很大的可比性缺乏。在这些测试的测量可以在临床实践中使用之前,需要进一步努力实现这些测试的协调。