University of Belgrade, School of Dental Medicine, Department of Prosthodontics, Belgrade, Serbia.
University of Belgrade, School of Dental Medicine, DentalNet Research Group, Belgrade, Serbia.
J Esthet Restor Dent. 2023 Sep;35(6):917-926. doi: 10.1111/jerd.13045. Epub 2023 Apr 11.
To evaluate the effect of different finishing and polishing procedures on surface roughness and microbial adhesion and viability of Streptococcus mutans on novel highly-filled composites for injectable mold technique.
One hundred sixty specimens were divided into four material groups: FSF (Filtek Supreme Flowable Restorative), TE (Tetric EvoFlow), GUI (G-aenial Universal Injectable) and GUF (G-aenial Universal Flo). Within each group, specimens were split regarding finishing and polishing (F/P) procedures into: SLD (Sof-Lex Discs), SLS (Sof-Lex Spirals), OG (OneGloss) and PG (PoGo). Surface roughness was analyzed using profilometer (Ra and Rz) and scanning electron microscopy (SEM) and Strep. mutans biofilm formation was analyzed using colony forming unit (CFU) and cell viability assay. Two-way analysis of variance (ANOVA) followed by Tukey's post hoc test were used for comparison among groups, Pearson's coefficient was applied for the correlation between Ra and CFU/ml and all data were presented as mean ± SD.
Both materials and F/P procedures affect Ra, Rz and Strep. mutans CFU/ml values (p ≤ 0.05). Considering the Ra and Rz, GUI and GUF revealed lower values, compared to FSF and TE and SLD and SLS revealed lower values, compared to OG and PG. Considering the Strep. mutans CFU/ml and viability, GUI and TE presented lower values, compared to GUF and FSF and SLD and SLS presented lower values, compared to OG and PG. Moderate positive correlation was found between Ra and CFU/ml (r = 0.552).
The smoothest surfaces possess GUI and GUF, among materials and SLD and SLS, among F/P procedures. GUI adhered the lowest amount of Strep. mutans, due to the smoothest surfaces. FSF and GUF revealed the highest amount of Strep. mutans, due to bis-GMA, bis-MEPP and TEGDMA in their composition.
The findings of the present study may be beneficial for the proper selection of highly-filled composites and an adequate finishing and polishing procedure when performing the injectable mold composite resin veneer technique.
评估不同的修整和抛光程序对新型高填充注塑模具技术用复合材料表面粗糙度和变形链球菌黏附及活力的影响。
将 160 个样本分为 4 个材料组:Filtek Supreme Flowable Restorative(FSF)、Tetric EvoFlow(TE)、G-aenial Universal Injectable(GUI)和 G-aenial Universal Flo(GUF)。每组样本根据修整和抛光(F/P)程序分为:Sof-Lex Discs(SLD)、Sof-Lex Spirals(SLS)、OneGloss(OG)和 PoGo(PG)。使用轮廓仪(Ra 和 Rz)和扫描电子显微镜(SEM)分析表面粗糙度,使用菌落形成单位(CFU)和细胞活力测定分析变形链球菌生物膜形成。采用双因素方差分析(ANOVA)和 Tukey 事后检验进行组间比较,Pearson 相关系数用于分析 Ra 和 CFU/ml 之间的相关性,所有数据均以平均值±标准差表示。
材料和 F/P 程序均影响 Ra、Rz 和变形链球菌 CFU/ml 值(p≤0.05)。考虑 Ra 和 Rz,GUI 和 GUF 比 FSF 和 TE 的值低,SLD 和 SLS 比 OG 和 PG 的值低。考虑变形链球菌 CFU/ml 和活力,GUI 和 TE 比 GUF 和 FSF 的值低,SLD 和 SLS 比 OG 和 PG 的值低。Ra 和 CFU/ml 之间存在中度正相关(r=0.552)。
在材料方面,最光滑的表面是 GUI 和 GUF,在 F/P 程序方面,最光滑的表面是 SLD 和 SLS。由于 GUI 表面最光滑,黏附的变形链球菌数量最少。由于其组成中含有双酚 A 二缩水甘油醚(Bis-GMA)、双甲基丙烯酸缩水甘油酯(Bis-MEPP)和三乙二醇二甲基丙烯酸酯(TEGDMA),FSF 和 GUF 中的变形链球菌数量最多。
本研究结果可能有助于在进行注塑模具复合树脂贴面技术时,正确选择高填充复合材料和适当的修整和抛光程序。