Department of Ophthalmology, Military Institute of Aviation Medicine, 01-755 Warsaw, Poland.
Medicina (Kaunas). 2023 Mar 27;59(4):658. doi: 10.3390/medicina59040658.
In patients with eye surface disorders such as dry eye syndrome or Meibomian gland dysfunction (MGD) it is necessary to improve the tear film condition in order to obtain visual system measurements before cataract surgery. The aim of the project was to analyze the Thermal Pulsation System (TPS) impact on the visual system parameters used in cataract surgery qualification. The study included six patients (11 eyes) with MGD diagnosis. All patients were treated with TPS. The obtained results were compared and used to calculate the power and type of the intraocular lens (IOL). As a treatment result, the power of astigmatism has changed in 64% of the eyes. Planned surgical treatment type has changed in 27% of cases. TPS also affected the cylinder axis in three eyes, which was 27% of cases. Based on the calculations, power of the recommended IOL has changed in five eyes (46%). Stabilization of visual system parameters after TPS allowed to improve the accuracy of the results. It also ensured the proper astigmatism treating method during cataract surgery and allowed selection of the proper IOL power and type.
在患有眼表面疾病(如干眼症或睑板腺功能障碍(MGD))的患者中,有必要改善泪膜状况,以便在白内障手术前获得视觉系统测量结果。该项目的目的是分析热脉冲系统(TPS)对白内障手术资格中使用的视觉系统参数的影响。该研究包括 6 名(11 只眼)患有 MGD 诊断的患者。所有患者均接受 TPS 治疗。比较获得的结果并用于计算人工晶状体(IOL)的功率和类型。作为治疗结果,64%的眼睛的散光功率发生了变化。27%的情况下计划的手术治疗类型发生了变化。TPS 还影响了三眼中的圆柱轴,占 27%的病例。根据计算,推荐的 IOL 功率在 5 只眼中(46%)发生了变化。TPS 后视觉系统参数的稳定化提高了结果的准确性。它还确保了白内障手术中正确的散光治疗方法,并允许选择适当的 IOL 功率和类型。