Suppr超能文献

猫的胆胰管造影术:MRI 与透视、腐蚀铸造和组织病理学的死后比较。

Cholangiopancreatography in cats: a post-mortem comparison of MRI with fluoroscopy, corrosion casting and histopathology.

机构信息

Department of Equine and Small Animal Medicine, Faculty of Veterinary Medicine, University of Helsinki, Helsinki, Finland.

HUS Medical Imaging Center, Radiology, Helsinki University Hospital, University of Helsinki, Helsinki, Finland.

出版信息

Vet Radiol Ultrasound. 2023 Jul;64(4):713-723. doi: 10.1111/vru.13240. Epub 2023 May 3.

Abstract

In human medicine, magnetic resonance cholangiopancreatography (MRCP) is a valuable diagnostic tool for hepatobiliary and pancreatic diseases. In veterinary medicine, however, data evaluating the diagnostic value of MRCP are limited. The primary objectives of this prospective, observational, analytical investigation were to assess whether MRCP reliably visualizes the biliary tract and pancreatic ducts in cats without and with related disorders, and whether MRCP images and measurements of the ducts agree with those of fluoroscopic retrograde cholangiopancreatography (FRCP), corrosion casting and histopathology. A secondary objective was to provide MRCP reference diameters for bile ducts, GB, and pancreatic ducts. Donated bodies of 12 euthanized adult cats underwent MRCP, FRCP, and autopsy with corrosion casting of the biliary tract and pancreatic ducts using vinyl polysiloxane. Diameters of the biliary ducts, gallbladder (GB), and pancreatic ducts were measured using MRCP, FRCP, corrosion casts and histopathologic slides. There was an agreement between MRCP and FRCP in measuring diameters of the GB body, GB neck, cystic duct, and common bile duct (CBD) at papilla. Strong positive correlations existed between MRCP and corrosion casting for measuring GB body and neck, cystic duct, and CBD at the extrahepatic ducts' junction. In contrast to the reference methods, post-mortem MRCP did not visualize right and left extrahepatic ducts, and pancreatic ducts in most cats. Based on this study, MRCP with 1.5 Tesla can be regarded as a contributory method to improve the assessment of feline biliary tract and pancreatic ducts when their diameter is >1 mm.

摘要

在人类医学中,磁共振胰胆管成像(MRCP)是一种用于肝胆和胰腺疾病的有价值的诊断工具。然而,在兽医医学中,评估 MRCP 诊断价值的数据有限。本前瞻性、观察性、分析性研究的主要目的是评估 MRCP 是否能够可靠地显示无相关疾病和有相关疾病的猫的胆道和胰管,并评估 MRCP 图像和导管测量结果是否与荧光逆行胰胆管造影(FRCP)、腐蚀铸造和组织病理学一致。次要目标是提供胆管、胆囊(GB)和胰管的 MRCP 参考直径。12 只已安乐死的成年猫的尸体接受了 MRCP、FRCP 和尸检,并使用乙烯基聚硅氧烷对胆道和胰管进行了腐蚀铸造。使用 MRCP、FRCP、腐蚀铸型和组织病理学切片测量胆管、胆囊(GB)和胰管的直径。在测量胆囊体、胆囊颈、胆囊管和乳头处胆总管(CBD)的直径时,MRCP 和 FRCP 之间存在一致性。MRCP 与腐蚀铸造在测量胆囊体和颈部、胆囊管和肝外胆管交界处的胆总管方面存在强正相关。与参考方法相比,大多数猫死后的 MRCP 无法显示右肝外胆管和左肝外胆管以及胰管。基于这项研究,1.5 特斯拉的 MRCP 可以被视为一种辅助方法,用于改善对猫胆管和胰管的评估,当它们的直径>1mm 时。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验