Assessment of Silicone Oil Emulsification: A Comparison of Currently Applied Methods.

作者信息

Zhao Hongmei, Chen Qian, Yu Jian, Wu Kaicheng, Zong Yuan, Jiang Chunhui, Zhu Haohao, Xu Gezhi

机构信息

Department of Ophthalmology and Vision Science, Eye and ENT Hospital, Fudan University, Shanghai 200031, China.

Key Laboratory of Myopia of State Health Ministry, Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai 200031, China.

出版信息

J Ophthalmol. 2023 Apr 24;2023:8114530. doi: 10.1155/2023/8114530. eCollection 2023.

Abstract

PURPOSE

To compare ultrasound biomicroscopy (UBM), Coulter counter, and B-scan ultrasonography in the evaluation of silicone oil (SO) emulsification.

METHODS

Patients who underwent primary pars plana vitrectomy with SO tamponade for rhegmatogenous retinal detachment and SO removal were included. UBM images were acquired before the SO removal, and B-scan images were taken after removal. The number of droplets in the first and last 2 mL of washout fluid was analyzed using a Coulter counter. The correlations between these measurements were analyzed.

RESULTS

Thirty-four eyes received both UBM and Coulter counter analysis for the first 2 mL of washout fluid, and 34 underwent B-scan and Coulter counter analysis of the last 2 mL washout fluid. The mean UBM grading was 26.41 ± 9.71 (range: 1-36); the mean SO index obtained with B-scan was 5.25 ± 5.00% (range: 0.10-16.49%), and the mean number of SO droplets was 1.26 ± 2.45 × 10/mL and 3.34 ± 4.22 × 10/mL in the first and last 2 mL of washout fluid, respectively. There were significant correlations between UBM grading and SO droplets in the first 2 mL and between B-scan grading and SO droplets in the last 2 mL (all < 0.05).

CONCLUSIONS

UBM, Coulter counter, and B-scan ultrasonography could all be used in the evaluation of SO emulsification, and their findings were comparable.

摘要

目的

比较超声生物显微镜(UBM)、库尔特计数器和B型超声检查在硅油(SO)乳化评估中的应用。

方法

纳入接受原发性玻璃体切除术联合SO填充治疗孔源性视网膜脱离并进行SO取出的患者。在取出SO之前采集UBM图像,取出后拍摄B型超声图像。使用库尔特计数器分析冲洗液最初2 mL和最后2 mL中的液滴数量。分析这些测量结果之间的相关性。

结果

34只眼对冲洗液最初2 mL进行了UBM和库尔特计数器分析,34只眼对冲洗液最后2 mL进行了B型超声和库尔特计数器分析。UBM平均分级为26.41±9.71(范围:1 - 36);B型超声获得的SO指数平均为5.25±5.00%(范围:0.10 - 16.49%),冲洗液最初2 mL和最后2 mL中SO液滴的平均数量分别为1.26±2.45×10/mL和3.34±4.22×10/mL。UBM分级与最初2 mL中的SO液滴之间以及B型超声分级与最后2 mL中的SO液滴之间存在显著相关性(均P<0.05)。

结论

UBM、库尔特计数器和B型超声检查均可用于SO乳化的评估,且它们的结果具有可比性。

相似文献

1
Assessment of Silicone Oil Emulsification: A Comparison of Currently Applied Methods.
J Ophthalmol. 2023 Apr 24;2023:8114530. doi: 10.1155/2023/8114530. eCollection 2023.
3
Characteristics of Silicone Oil Emulsification After Vitrectomy for Rhegmatogenous Retinal Detachment: An Ultrasound Biomicroscopy Study.
Front Med (Lausanne). 2022 Jan 13;8:794786. doi: 10.3389/fmed.2021.794786. eCollection 2021.
4
Comparison of Repeated Fluid-Air Exchange and Passive Drainage for Removing Residual Emulsified Silicone Oil Droplets.
J Ophthalmol. 2020 Jul 4;2020:8184607. doi: 10.1155/2020/8184607. eCollection 2020.
5
Silicone Oil Emulsification after Vitrectomy for Rhegmatogenous Retinal Detachment.
J Ophthalmol. 2020 Feb 24;2020:6940625. doi: 10.1155/2020/6940625. eCollection 2020.
8
Quantifying silicone oil emulsification in patients: are we only seeing the tip of the iceberg?
Graefes Arch Clin Exp Ophthalmol. 2015 Oct;253(10):1671-5. doi: 10.1007/s00417-014-2866-1. Epub 2014 Nov 25.
9
Timing of retinal redetachment after removal of intraocular silicone oil tamponade.
Am J Ophthalmol. 1999 Nov;128(5):628-31. doi: 10.1016/s0002-9394(99)00201-9.

引用本文的文献

本文引用的文献

1
Characteristics of Silicone Oil Emulsification After Vitrectomy for Rhegmatogenous Retinal Detachment: An Ultrasound Biomicroscopy Study.
Front Med (Lausanne). 2022 Jan 13;8:794786. doi: 10.3389/fmed.2021.794786. eCollection 2021.
2
What Is the Cause of Toxicity of Silicone Oil?
Materials (Basel). 2021 Dec 30;15(1):269. doi: 10.3390/ma15010269.
3
Comparison of Repeated Fluid-Air Exchange and Passive Drainage for Removing Residual Emulsified Silicone Oil Droplets.
J Ophthalmol. 2020 Jul 4;2020:8184607. doi: 10.1155/2020/8184607. eCollection 2020.
4
Silicone Oil Emulsification after Vitrectomy for Rhegmatogenous Retinal Detachment.
J Ophthalmol. 2020 Feb 24;2020:6940625. doi: 10.1155/2020/6940625. eCollection 2020.
5
A perfluorobutylpentane (F4H5)-based solution for the removal of residual emulsified silicone oil.
Acta Ophthalmol. 2018 Feb;96(1):e38-e45. doi: 10.1111/aos.13465. Epub 2017 Jun 14.
6
Effect of fluid-air exchange on reducing residual silicone oil after silicone oil removal.
Graefes Arch Clin Exp Ophthalmol. 2017 Sep;255(9):1697-1704. doi: 10.1007/s00417-017-3701-2. Epub 2017 Jun 14.
8
9
Quantifying silicone oil emulsification in patients: are we only seeing the tip of the iceberg?
Graefes Arch Clin Exp Ophthalmol. 2015 Oct;253(10):1671-5. doi: 10.1007/s00417-014-2866-1. Epub 2014 Nov 25.
10
Complications of emulsified silicone oil after retinal detachment repair.
Semin Ophthalmol. 2014 Sep-Nov;29(5-6):312-8. doi: 10.3109/08820538.2014.962181.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验