Suppr超能文献

评估带有锥形邻接体的夹板修复体在多个非平行种植体上的脱位力(体外研究)。

Evaluation of the dislodgement force of splinted restorations with engaging conical abutments over multiple nonparallel implants (in-vitro study).

机构信息

Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.

Division of Fixed Prosthodontics, Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.

出版信息

BMC Oral Health. 2023 May 17;23(1):300. doi: 10.1186/s12903-023-02958-4.

Abstract

BACKGROUND

Splinted multiunit cement-retained restorations with screw access channels over engaging abutments are viable implant prosthetic options. However, information regarding the maximum degree of divergence between multiple implants is lacking. The purpose of this in vitro study was to determine the maximum degree of divergence between 2 adjacent implants with conical connections that allows insertion and removal of splinted restorations with engaging preparable abutments or titanium base abutments.

METHODS

Two implants were aligned in a stone base, one straight and the other at an angle ranging from 0 to 20 degrees. The implants represented an implant system that had an internal conical connection and a hexed abutment engaging the base of the connection. Two straight preparable engaging cement retained abutments were screwed onto the implants and splinted together using acrylic resin. A total of 11 angles were tested, with 7 specimens for every angle. Evaluation of dislodging force was performed by pulling out the splinted abutments after unscrewing them. This was performed subjectively by 3 blinded investigators who applied a tactile pulling force. A scale of 0-10 was used to estimate the pulling force. Objectively the dislodging force was measured in Newtons using a universal testing machine. A statistical correlation was made between the subjective and objective dislodging force values using Spearman's rank correlation coefficient.

RESULTS

The mean subjective values increased gradually from 0 to 16 degrees. A sudden rise was noticed at 18 degrees (9.71 ± 0.23) and, at 20 degrees, the investigators were not able to remove the splinted abutments from the implants. The mean objective dislodgement force values increased gradually from 0 to16 degrees and abruptly from 16 degrees (13.57 ± 0.45 N) to 18 degrees (25.40 ± 0.66 N) and 20 degrees (35.22 ± 0.64). The correlation between the subjective and the objective evaluations assessed using the Spearman's rank correlation coefficient was 0.98 indicating a statistically significant correlation (P < .001). As the objective dislodging force increased, the subjective dislodgement difficulty increased.

CONCLUSIONS

Splinting cement retained restorations with screw access channels on engaging abutments is possible when multiple implants with conical connections having an internal flare angle of 8 degrees are used, with implant divergence of up to 16 degrees.

摘要

背景

带有螺丝通道的多单位固位粘结修复体,其基台具有锁合功能,是可行的种植体修复选择。然而,关于多个种植体之间最大分歧程度的信息尚不清楚。本体外研究的目的是确定具有锥形连接的 2 个相邻种植体之间的最大分歧程度,该分歧程度允许插入和移除带有预备可粘结基台或钛基底台的粘结修复体。

方法

将两个种植体在石基中对齐,一个是直的,另一个角度为 0 到 20 度。这些种植体代表了一种具有内部锥形连接和六角基台与连接底部相接合的种植系统。将两个直的预备可粘结的粘结固位基台拧到种植体上,并用丙烯酸树脂将它们固定在一起。共测试了 11 个角度,每个角度有 7 个样本。通过拧下后拔出粘结基台来评估脱位力。由 3 名盲法观察者通过触觉施加拉力来进行主观评估。使用 0-10 的量表来估计拉力。使用万能试验机以牛顿为单位客观测量脱位力。使用 Spearman 等级相关系数对主观和客观脱位力值进行了统计学相关性分析。

结果

主观值从 0 度逐渐增加到 16 度。在 18 度时突然上升(9.71±0.23),在 20 度时,观察者无法将粘结基台从种植体上取下。客观脱位力值从 0 度逐渐增加到 16 度,然后在 16 度(13.57±0.45 N)至 18 度(25.40±0.66 N)和 20 度(35.22±0.64 N)突然增加。使用 Spearman 等级相关系数评估的主观和客观评估之间的相关性为 0.98,表明具有统计学显著相关性(P<.001)。随着客观脱位力的增加,主观脱位难度也增加。

结论

当使用具有 8 度内部扩孔角的锥形连接的多个种植体时,带有螺丝通道的粘结固位修复体是可行的,最大种植体分歧角度为 16 度。