Suppr超能文献

伴侣犬的视网膜电图测量在年龄相关变化。

Age-associated changes in electroretinography measures in companion dogs.

机构信息

Department of Surgical Sciences, Medical Sciences Center, School of Veterinary Medicine, University of Wisconsin-Madison, 1300 University Avenue, Madison, WI, 53706, USA.

Department of Population Health Sciences, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, USA.

出版信息

Doc Ophthalmol. 2023 Aug;147(1):15-28. doi: 10.1007/s10633-023-09938-7. Epub 2023 Jun 11.

Abstract

PURPOSE

To determine the association between age and retinal full-field electroretinographic (ERG) measures in companion (pet) dogs, an important translational model species for human neurologic aging.

METHODS

Healthy adult dogs with no significant ophthalmic abnormalities were included. Unilateral full-field light- and dark-adapted electroretinography was performed using a handheld device, with mydriasis and topical anaesthesia. Partial least squares effect screening analysis was performed to determine the effect of age, sex, body weight and use of anxiolytic medication on log-transformed ERG peak times and amplitudes; age and anxiolytic usage had significant effects on multiple ERG outcomes. Mixed model analysis was performed on data from dogs not receiving anxiolytic medications.

RESULTS

In dogs not receiving anxiolytics, median age was 118 months (interquartile range 72-140 months, n = 77, 44 purebred, 33 mixed breed dogs). Age was significantly associated with prolonged peak times of a-waves (dark-adapted 3 and 10 cds/m flash p < 0.0001) and b-waves (cone flicker p = 0.03, dark-adapted 0.01 cds/m flash p = 0.001). Age was also significantly associated with reduced amplitudes of a-waves (dark-adapted 3 cds/m flash p < 0.0001, 10 cds/m flash p = 0.005) and b-waves (light-adapted 3 cds/m flash p < 0.0001, dark-adapted 0.01 cds/m flash p = 0.0004, 3 cds/m flash p < 0.0001, 10 cds/m flash p = 0.007) and flicker (light-adapted 30 Hz 3 cds/m p = 0.0004). Within the Golden Retriever breed, these trends were matched in a cross-sectional analysis of 6 individuals that received no anxiolytic medication.

CONCLUSIONS

Aged companion dogs have slower and reduced amplitude responses in both rod- and cone-mediated ERG. Consideration of anxiolytic medication use should be made when conducting ERG studies in dogs.

摘要

目的

确定年龄与伴侣(宠物)犬视网膜全视野视网膜电图(ERG)测量值之间的关系,犬是人类神经老化的重要转化模型物种。

方法

纳入无明显眼部异常的健康成年犬。使用手持式设备进行单侧全视野明、暗适应视网膜电图检查,散瞳和局部麻醉。采用偏最小二乘效应筛选分析确定年龄、性别、体重和使用抗焦虑药物对 log 转换 ERG 峰时和振幅的影响;年龄和抗焦虑药物使用对多种 ERG 结果有显著影响。对未使用抗焦虑药物的犬进行混合模型分析。

结果

在未使用抗焦虑药物的犬中,中位年龄为 118 个月(四分位间距 72-140 个月,n=77,44 只为纯种犬,33 只为混种犬)。年龄与 a 波峰时延长(暗适应 3 和 10 cd/s/m 闪烁 p<0.0001)和 b 波(视锥闪烁 p=0.03,暗适应 0.01 cd/s/m 闪烁 p=0.001)显著相关。年龄还与 a 波振幅降低(暗适应 3 cd/s/m 闪烁 p<0.0001,10 cd/s/m 闪烁 p=0.005)和 b 波振幅降低(明适应 3 cd/s/m 闪烁 p<0.0001,暗适应 0.01 cd/s/m 闪烁 p=0.004,3 cd/s/m 闪烁 p<0.0001,10 cd/s/m 闪烁 p=0.007)和闪烁(明适应 30 Hz 3 cd/s/m p=0.0004)显著相关。在没有使用抗焦虑药物的 6 只金毛猎犬的横断面分析中,这些趋势是一致的。

结论

老年伴侣犬在棒状和视锥介导的 ERG 中反应速度较慢,振幅降低。在犬进行 ERG 研究时,应考虑使用抗焦虑药物。

相似文献

1
Age-associated changes in electroretinography measures in companion dogs.
Doc Ophthalmol. 2023 Aug;147(1):15-28. doi: 10.1007/s10633-023-09938-7. Epub 2023 Jun 11.
2
Full-field electroretinogram in autism spectrum disorder.
Doc Ophthalmol. 2016 Apr;132(2):83-99. doi: 10.1007/s10633-016-9529-y. Epub 2016 Feb 11.
3
Evaluation of light- and dark-adapted ERGs using a mydriasis-free, portable system: clinical classifications and normative data.
Doc Ophthalmol. 2018 Dec;137(3):169-181. doi: 10.1007/s10633-018-9660-z. Epub 2018 Oct 24.
4
ISCEV extended protocol for the dark-adapted red flash ERG.
Doc Ophthalmol. 2018 Jun;136(3):191-197. doi: 10.1007/s10633-018-9644-z. Epub 2018 Jun 22.
5
Two-color pupillometry in KCNV2 retinopathy.
Doc Ophthalmol. 2019 Aug;139(1):11-20. doi: 10.1007/s10633-019-09691-w. Epub 2019 Mar 29.
6
ISCEV Standard for full-field clinical electroretinography (2015 update).
Doc Ophthalmol. 2015 Feb;130(1):1-12. doi: 10.1007/s10633-014-9473-7. Epub 2014 Dec 14.
8
Rod-driven OFF pathway responses in the distal retina: dark-adapted flicker electroretinogram in mouse.
PLoS One. 2012;7(8):e43856. doi: 10.1371/journal.pone.0043856. Epub 2012 Aug 24.
9
Enhanced retinal responses in Huntington's disease patients.
J Huntingtons Dis. 2017;6(3):237-247. doi: 10.3233/JHD-170255.
10
Reduction of Rod and Cone Function in 6.5-Year-Old Children Born Extremely Preterm.
JAMA Ophthalmol. 2017 Aug 1;135(8):854-861. doi: 10.1001/jamaophthalmol.2017.2069.

引用本文的文献

4
Dual sensory impairments in companion dogs: Prevalence and relationship to cognitive impairment.
PLoS One. 2024 Oct 16;19(10):e0310299. doi: 10.1371/journal.pone.0310299. eCollection 2024.
5
Cross-sectional and longitudinal analysis of health-related quality of life (HRQoL) in senior and geriatric dogs.
PLoS One. 2024 Sep 4;19(9):e0301181. doi: 10.1371/journal.pone.0301181. eCollection 2024.
6
Differential gene expression between central and peripheral retinal regions in dogs and comparison with humans.
Exp Eye Res. 2024 Aug;245:109980. doi: 10.1016/j.exer.2024.109980. Epub 2024 Jun 22.
7
Screen interaction behavior in companion dogs: results from a dog owner survey.
Appl Anim Behav Sci. 2024 Jan;270. doi: 10.1016/j.applanim.2023.106151. Epub 2023 Dec 26.
8
Subjective vision assessment in companion dogs using dogVLQ demonstrates age-associated visual dysfunction.
Front Vet Sci. 2023 Aug 17;10:1244518. doi: 10.3389/fvets.2023.1244518. eCollection 2023.

本文引用的文献

1
Effects of gabapentin and trazodone on electroretinographic responses in clinically normal dogs.
Am J Vet Res. 2022 Jun 13;83(8):ajvr.22.03.0047. doi: 10.2460/ajvr.22.03.0047.
3
Alzheimer's Disease Seen through the Eye: Ocular Alterations and Neurodegeneration.
Int J Mol Sci. 2022 Feb 24;23(5):2486. doi: 10.3390/ijms23052486.
4
Use of extended protocols with nonstandard stimuli to characterize rod and cone contributions to the canine electroretinogram.
Doc Ophthalmol. 2022 Apr;144(2):81-97. doi: 10.1007/s10633-022-09866-y. Epub 2022 Mar 5.
5
Sustained Gaze Is a Reliable In-home Test of Attention for Aging Pet Dogs.
Front Vet Sci. 2021 Dec 23;8:819135. doi: 10.3389/fvets.2021.819135. eCollection 2021.
6
Comparison among TonoVet, TonoVet Plus, Tono-Pen Avia Vet, and Kowa HA-2 portable tonometers for measuring intraocular pressure in dogs.
Vet World. 2021 Sep;14(9):2444-2451. doi: 10.14202/vetworld.2021.2444-2451. Epub 2021 Sep 21.
7
Retinal imaging biomarkers of neurodegenerative diseases.
Clin Exp Optom. 2022 Mar;105(2):194-204. doi: 10.1080/08164622.2021.1984179. Epub 2021 Nov 9.
9
Multimodal retinal imaging to detect and understand Alzheimer's and Parkinson's disease.
Curr Opin Neurobiol. 2022 Feb;72:1-7. doi: 10.1016/j.conb.2021.07.007. Epub 2021 Aug 14.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验