[Determination of stenotic mitral valve area using Doppler echocardiography. A comparison with hemodynamic studies].

作者信息

Moro E, Roelandt J

出版信息

G Ital Cardiol. 1986 May;16(5):411-6.

PMID:3732726
Abstract

In order to assess the reliability of Doppler echocardiography in the determination of mitral valve area (MVA) 21 consecutive patients (pts) affected by rheumatic disease and mitral valve stenosis (MS) were analyzed by continuous wave doppler echocardiography (CWD). Cardiac catheterization (cath) was performed within 24 hours from echocardiographic examination. MVA by CWD was calculated with a computerized system from the "pressure half-time" (T1/2) using the equation: 220/T1/2 in cm2. MVA was calculated from cath data by applying the modified Gorlin formula. MVA determined by CWD ranged from 0.9 to 2.8 cm2 (mean 1.39 +/- 0.55). MVA determined by Gorlin formula ranged from 0.5 to 2.8 cm2 (mean 1.31 +/- 0.63). The correlation between CWD and cath was good (r = 0.93, SEE = 0.19 cm2, P less than 0.001). In conclusion this study indicates that CWD is quite accurate in estimation of MVA and can reliably discriminate the "critical" size of the orifice. CWD has the advantage of allowing MVA determination in patients with associated mitral regurgitation.

摘要

相似文献

1
[Determination of stenotic mitral valve area using Doppler echocardiography. A comparison with hemodynamic studies].
G Ital Cardiol. 1986 May;16(5):411-6.
2
[Determination of the transvalvular gradient using continuous wave Doppler in patients with mitral stenosis. Correlation with the hemodynamic method].[二尖瓣狭窄患者连续波多普勒测定跨瓣压差。与血流动力学方法的相关性]
G Ital Cardiol. 1987 Apr;17(4):306-10.
3
[Doppler sonography quantification of mitral valve stenosis in patients with and without mitral valve insufficiency].
Z Kardiol. 1986 Oct;75(10):598-604.
4
[Non-invasive estimation of transmitral pressure gradient and mitral valve area in mitral stenosis by an ultrasonic pulsed Doppler technique].[应用超声脉冲多普勒技术无创评估二尖瓣狭窄时的跨二尖瓣压力阶差和二尖瓣瓣口面积]
J Cardiogr. 1984 Jun;14(1):149-61.
5
[Doppler sonographic determination of the degree of severity of mitral valve stenoses].[二尖瓣狭窄严重程度的多普勒超声心动图测定]
Z Kardiol. 1985 Jan;74(1):23-31.
6
[Comparison of continuous wave Doppler and heart catheterization in the determination of the mean transvalvular gradient in mitral stenosis. A simultaneous beat to beat analysis].[连续波多普勒与心导管检查在测定二尖瓣狭窄平均跨瓣压差中的比较。同步逐搏分析]
G Ital Cardiol. 1988 Apr;18(4):308-12.
7
[Continuous wave Doppler measurement of transmitral pressure gradients in mitral stenosis: comparisons with simultaneous catheterization measurements].[二尖瓣狭窄时经二尖瓣压力阶差的连续波多普勒测量:与同步心导管测量结果的比较]
J Cardiogr. 1985 Dec;15(4):1097-107.
8
[Validity of the proximal isovelocity surface area color Doppler method for calculating the valve area in patients with mitral stenosis; comparison with the two-dimensional echocardiographic method].[近端等速表面积彩色多普勒法计算二尖瓣狭窄患者瓣膜面积的有效性;与二维超声心动图法的比较]
G Ital Cardiol. 1992 Oct;22(10):1201-10.
9
The importance of quantitative Doppler in assessment of mitral stenosis.定量多普勒在二尖瓣狭窄评估中的重要性。
Cor Vasa. 1986;28(6):451-7.
10
[Doppler-echocardiographic determination of the degree of severity of mitral stenosis].[二尖瓣狭窄严重程度的多普勒超声心动图测定]
Herz. 1984 Aug;9(4):222-30.