Suppr超能文献

对犬选定超声心动图测量值的操作者间和操作者内变异性的研究。

A study of the inter- and intra-operator variability on selected echocardiographic measurements in dogs.

机构信息

Department of Veterinary Medicine and Animal Sciences - DIVAS, University of Milan, Lodi, LO, 26900, Italy.

Department of Cardiology, Clinica Veterinaria Gran Sasso, Milan, MI, 20131, Italy.

出版信息

Vet Res Commun. 2023 Dec;47(4):2323-2331. doi: 10.1007/s11259-023-10154-6. Epub 2023 Jun 23.

Abstract

Standard transthoracic echocardiography is considered the non-invasive gold standard for the diagnosis of most cardiac diseases. Defining reproducibility, repeatability, and reliability of this exam is imperative to reduce errors in clinical evaluations. The present study aimed at: (1) evaluating the reproducibility and repeatability of 15 echocardiographic parameters in dogs by analyzing measurements obtained from several operators with different levels of experience and comparing them to the ones obtained from two board-certified operators (gold standards - GSs); (2) assessing whether different formative paths have an influence on the variability of the echocardiographic measurements. Fifty-one operators have been included in this study, along with two diplomates of the European College of Veterinary Internal Medicine - Cardiology. Ten dogs were enrolled, 5 Golden Retrievers and 5 Cavalier King Charles Spaniels. Echocardiographic examination was performed on each dog by one GS and several operators on the same day. Results show the highest deviation from the GS and a poor inter-operator reproducibility for the M-mode measurements of the interventricular septum and the left ventricular free wall. Differently, M-mode-obtained internal diameters of the left ventricle in systole and diastole, and measurements of the aortic annulus and root show moderate to excellent intra- and inter-operator reliability and a good concordance with the GSs, demonstrating that all the operators correctly assess left ventricular systolic function and dilation, and evaluate the aortic valve. Furthermore, a specialist clinical activity, more than the acquired theoretical knowledge, affects the reliability of the echocardiographic examination by reducing the difference from the GS' measurements.

摘要

标准经胸超声心动图被认为是诊断大多数心脏疾病的非侵入性金标准。为了减少临床评估中的错误,必须定义该检查的可重复性、可重复性和可靠性。本研究旨在:(1) 通过分析具有不同经验水平的多个操作者获得的测量值,评估 15 个超声心动图参数在犬中的可重复性和可重复性,并将其与两名经过 board-certified 认证的操作者(金标准 - GS)获得的测量值进行比较;(2) 评估不同的形成路径是否对超声心动图测量值的变异性有影响。本研究纳入了 51 名操作者,以及两名欧洲兽医内科学会心脏病学的专科医生。10 只狗被纳入研究,其中 5 只为金毛猎犬,5 只为骑士查理王小猎犬。每只狗都由一名 GS 和多名操作者在同一天进行超声心动图检查。结果显示,与 GS 相比,M 型测量的室间隔和左心室游离壁的偏差最大,且操作者之间的可重复性较差。相反,M 型测量的左心室收缩期和舒张期内径,以及主动脉瓣环和根部的测量值具有中等到极好的操作者内和操作者间可靠性,并且与 GS 具有良好的一致性,表明所有操作者都能正确评估左心室收缩功能和扩张,并评估主动脉瓣。此外,专业的临床活动,而不是获得的理论知识,通过减少与 GS 测量值的差异,影响超声心动图检查的可靠性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d8c9/10698089/8ae4aa32bbbb/11259_2023_10154_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验