IMT Nord Europe, Institut Mines-Telecom, Centre for Energy and Environment, University Lille, 59000 Lille, France.
GINGER-BURGEAP, 19 Rue de la Villette, CEDEX 3, 69425 Lyon, France.
Molecules. 2023 Jun 26;28(13):5001. doi: 10.3390/molecules28135001.
Vapor intrusion is detrimental for indoor air quality. One of the most common sources of vapor intrusion is soil contaminated with petroleum hydrocarbons. To evaluate the long-term risk from individual exposure to hydrocarbons it is necessary to measure quantitively and reliably an average concentration level of individual pollutants on a monthly or yearly basis. Temporal variability of vapor intrusion from hydrocarbons poses a significant challenge to determination of average exposure and there is a need for reliable long-term integrative sampling. To this end, an analytical method for determination of 10 selected nonmethane hydrocarbons (NMHCs), including hexane, heptane, octane, decane, benzene, toluene, ethyl-benzene, m,p-xylene, o-xylene, and naphthalene, sampled on active triple-bed tubes filled with Carbograph 2, Carbograph 1, and Carboxen 1003 adsorbents was developed and validated. Extensive laboratory studies proved the absence of breakthrough at 50% HR and ambient temperature for experiments lasting up to 28 days and established a safe sampling time/volume of 20 days/114 L when sampling at a low flow rate of around 4 mL min. In addition, the developed method includes detailed uncertainty calculations for determination of concentrations. Finally, the method was tested by measuring NMHC concentrations in indoor air at a former industrial site during a 2-month-long field campaign in Lyon. The results of the field campaign suggest that 4-week integrated concentration measurements can be achieved by using active sampling on triple-bed tubes at 4.5 mL min.
蒸气侵入对室内空气质量有害。蒸气侵入的最常见来源之一是受石油碳氢化合物污染的土壤。为了评估个人接触碳氢化合物的长期风险,有必要每月或每年定量且可靠地测量个体污染物的平均浓度水平。碳氢化合物蒸气侵入的时间变异性对确定平均暴露量构成了重大挑战,因此需要可靠的长期综合采样。为此,开发并验证了一种在装有 Carbograph 2、Carbograph 1 和 Carboxen 1003 吸附剂的主动三床管上采集 10 种选定的非甲烷碳氢化合物(NMHCs)(包括己烷、庚烷、辛烷、癸烷、苯、甲苯、乙苯、间二甲苯、对二甲苯和萘)的分析方法。广泛的实验室研究证明,在 50% HR 和环境温度下,实验持续长达 28 天不会出现穿透,并且在低流量(约 4 mL min)下,建立了安全的采样时间/体积为 20 天/114 L。此外,该方法包括用于确定浓度的详细不确定度计算。最后,通过在里昂进行为期 2 个月的现场试验,在以前的工业现场测量室内空气中的 NMHC 浓度来测试该方法。现场试验的结果表明,通过在 4.5 mL min 的三床管上进行主动采样,可以实现 4 周的综合浓度测量。