Departament de Medicina i Cirurgia Animal, Facultat de Veterinària, Universitat Autònoma de Barcelona, Bellaterra, Spain.
Hospital Clínic Veterinari, Universitat Autònoma de Barcelona, Bellaterra, Spain.
Vet Clin Pathol. 2023 Sep;52(3):433-442. doi: 10.1111/vcp.13241. Epub 2023 Jul 19.
Immature platelets (IPs) are newly formed platelets released into circulation that have been demonstrated as good markers of thrombopoiesis. Although many flow cytometric and fully automated-based methods are available, the latest Sysmex XN-V hematology analyzer for veterinary use is equipped with a specific fluorescent platelet channel (PLT-F) that detects platelets using a platelet-specific dye.
The aims of this study were to evaluate the performance of the Sysmex XSN-1000 V in determining the IPF (immature platelet fraction) and other selected PLT-F channel parameters and to propose IPF reference intervals (RIs) for canine blood samples.
Canine EDTA blood samples were analyzed on the Sysmex XN-1000 V to assess linearity, imprecision, carryover, stability, and the effect of platelet clumping on selected platelet parameters from the PLT-F channel. We also reported the de novo generated RIs for the IPF in dogs.
Imprecision was acceptable (CV <10%) for all parameters except for the absolute IPF values (IPF#), in which the reproducibility was 12.15% for the normal-low concentration samples. Linearity and carryover were excellent for all variables. Relative IPF values (IPF %) and IPF# remained stable for both storage conditions for up to 48 hours; however, a nonsignificant progressive increase in these parameters was observed from 12 hours at 4°C. We observed a statistical increase in IPF% and IPF# and a statistically significant decrease in PLT-F counts after intentional in vitro platelet aggregation. RIs were generated for all reference samples (n = 69) and for samples with (n = 25) or without (n = 44) platelet clumps.
The performance of the new PLT-F channel-derived variables for dogs was excellent. Specific RIs for IPF should be used when platelet aggregates are present.
未成熟血小板(IPs)是新形成的血小板释放到循环中,已被证明是良好的血小板生成标志物。尽管有许多流式细胞术和全自动的方法可用,但最新的兽医专用希森美康 XN-V 血液分析仪配备了一个特定的荧光血小板通道(PLT-F),该通道使用血小板特异性染料来检测血小板。
本研究旨在评估希森美康 XSN-1000V 用于确定 IPF(未成熟血小板分数)和其他选定的 PLT-F 通道参数的性能,并为犬血样提出 IPF 参考区间(RI)。
用希森美康 XN-1000V 分析犬 EDTA 血样,以评估线性、不精密度、携带污染、稳定性以及血小板聚集对 PLT-F 通道中选定血小板参数的影响。我们还报告了犬中新生成的 IPF 的 RI。
除了绝对 IPF 值(IPF#)外,所有参数的不精密度均可接受(CV<10%),其中正常低值样本的重现性为 12.15%。所有变量的线性和携带污染均良好。相对 IPF 值(IPF%)和 IPF#在两种储存条件下均稳定,48 小时内无变化;然而,在 4°C 下 12 小时后,这些参数观察到非显著的逐渐增加。我们观察到 IPF%和 IPF#的统计学增加,以及体外血小板聚集后 PLT-F 计数的统计学显著下降。为所有参考样本(n=69)和有(n=25)或没有(n=44)血小板聚集的样本生成了 RI。
新的 PLT-F 通道衍生变量在犬中的性能优异。当存在血小板聚集时,应使用特定的 IPF RI。