Suppr超能文献

Sysmex XN 血液分析仪上未成熟血小板分数的参考区间:与 Sysmex XE-2100 的对比研究。

Reference interval for immature platelet fraction on Sysmex XN hematology analyzer: a comparison study with Sysmex XE-2100.

出版信息

Clin Chem Lab Med. 2015 Jun;53(7):1091-7. doi: 10.1515/cclm-2014-0839.

Abstract

BACKGROUND

Recently introduced hematology analyzer, the Sysmex XN modular system (Sysmex, Kobe, Japan), has newly adopted a florescent channel to detect platelets and immature platelet fraction (IPF). This study aimed to establish new reference intervals for %-IPF and absolute number of IPF (A-IPF) on Sysmex XN. Platelet counts, %-IPF, and A-IPF were also compared between Sysmex XN and XE-2100 systems (Sysmex).

METHODS

Except outliers, blood samples from 2104 healthy individuals and 140 umbilical cord blood were analyzed using both Sysmex XN and XE-2100. The results of two systems were compared using Bland-Altman plot. The reference intervals for %-IPF and A-IPF were defined using non-parametric percentile methods according to the Clinical and Laboratory Standard Institute guideline (C28-A3).

RESULTS

The platelet counts, %-IPF, and A-IPF showed non-parametric distributions. The mean difference between Sysmex XN and XE-2100 in healthy individuals revealed a positive bias in platelets (+8.0×109/L), %-IPF (+1.2%), and A-IPF (+3.0×109/L). The reference intervals for %-IPF and A-IPF on Sysmex XN were: 1.0%-7.3% and 2.49-15.64×109/L in healthy individuals; and 1.0%-4.4% and 2.94-12.82×109/L in umbilical cord blood.

CONCLUSIONS

This large-scale study demonstrates a clear difference of platelet counts and IPF between Sysmex XN and XE-2100. The new reference intervals for IPF on Sysmex XN would provide fundamental data for clinical practice and future research.

摘要

背景

最近推出的血液学分析仪,Sysmex XN 模块化系统(Sysmex,神户,日本),新采用荧光通道来检测血小板和未成熟血小板分数(IPF)。本研究旨在为 Sysmex XN 上的 %-IPF 和绝对 IPF 数(A-IPF)建立新的参考区间。还比较了 Sysmex XN 和 XE-2100 系统(Sysmex)之间的血小板计数、%-IPF 和 A-IPF。

方法

除离群值外,使用 Sysmex XN 和 XE-2100 分析了 2104 名健康个体和 140 份脐带血的血液样本。使用 Bland-Altman 图比较两种系统的结果。根据临床和实验室标准协会指南(C28-A3),使用非参数百分位数方法定义 %-IPF 和 A-IPF 的参考区间。

结果

血小板计数、%-IPF 和 A-IPF 呈非参数分布。健康个体中 Sysmex XN 与 XE-2100 之间的平均差异显示血小板(+8.0×109/L)、%-IPF(+1.2%)和 A-IPF(+3.0×109/L)呈正偏倚。Sysmex XN 上的 %-IPF 和 A-IPF 参考区间为:健康个体中为 1.0%-7.3%和 2.49-15.64×109/L;脐带血中为 1.0%-4.4%和 2.94-12.82×109/L。

结论

这项大规模研究表明 Sysmex XN 和 XE-2100 之间血小板计数和 IPF 存在明显差异。Sysmex XN 上 IPF 的新参考区间将为临床实践和未来研究提供基础数据。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验