Suppr超能文献

改用Vuse Vibe或Vuse Ciro电子尼古丁传送系统的吸烟者接触生物标志物和潜在危害的变化。

Changes in Biomarkers of Exposure and Potential Harm in Smokers Switched to Vuse Vibe or Vuse Ciro Electronic Nicotine Delivery Systems.

作者信息

Kanobe Milly N, Nelson Paul R, Brown Buddy G, Chen Peter, Makena Patrudu, Caraway John W, Prasad Gaddamanugu L, Round Elaine K

机构信息

RAI Services Company, 401 N. Main Street, Winston-Salem, NC 27101, USA.

Former Employees of RAI Services Company, 105 Bowes Road, Winston Salem, NC 27106, USA.

出版信息

Toxics. 2023 Jun 29;11(7):564. doi: 10.3390/toxics11070564.

Abstract

Electronic nicotine delivery systems (ENDS) have the potential to provide nicotine to tobacco consumers while reducing exposure to combustion-related toxicants. Here, we report changes in biomarkers of exposure (BoE) and biomarkers of potential harm (BoPH) in smokers who completely switched to Vuse Vibe and Vuse Ciro ENDS products, or to smoking abstinence in a randomized, controlled clinical study. Thirteen BoE (12 urinary and one blood) that indicate exposure to harmful and potentially harmful toxicants (HPHCs) were evaluated at baseline on day 5. Urinary BoPH linked to oxidative stress, platelet activation, and inflammation were also assessed at baseline, and on day 5 and day 7. Nicotine exposure was lower in Vuse Vibe and Vuse Ciro groups compared to baseline values. Urinary non-nicotine BoE decreased significantly (52.3-96.7%) in the Vuse ENDS groups, and the reductions were similar in magnitude to those observed in the abstinence group. Blood carboxyhemoglobin decreased 52.8-55.0% in all study groups. Decreases (10-50%) in BoPH were observed in all study groups. Thus, smokers who switch exclusively to Vuse Vibe or Vuse Ciro products or completely abstain from smoking are exposed to substantially lower levels of HPHCs, and experience improvements in BoPH of oxidative stress and inflammation pathways.

摘要

电子尼古丁输送系统(ENDS)有潜力为烟草消费者提供尼古丁,同时减少与燃烧相关的有毒物质暴露。在此,我们报告了在一项随机对照临床研究中,完全改用Vuse Vibe和Vuse Ciro ENDS产品的吸烟者或戒烟者体内暴露生物标志物(BoE)和潜在危害生物标志物(BoPH)的变化。在第5天基线时评估了13种表明暴露于有害和潜在有害有毒物质(HPHCs)的BoE(12种尿液和1种血液)。在基线以及第5天和第7天还评估了与氧化应激、血小板活化和炎症相关的尿液BoPH。与基线值相比,Vuse Vibe和Vuse Ciro组的尼古丁暴露较低。Vuse ENDS组的尿液非尼古丁BoE显著下降(52.3 - 96.7%),且下降幅度与戒烟组观察到的相似。所有研究组的血液碳氧血红蛋白下降了52.8 - 55.0%。所有研究组的BoPH均有下降(10 - 50%)。因此,完全改用Vuse Vibe或Vuse Ciro产品或完全戒烟的吸烟者接触的HPHCs水平大幅降低,并且在氧化应激和炎症途径的BoPH方面有所改善。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/650c/10384956/ef4fbfe8d76d/toxics-11-00564-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验