Lebbink Franciska, Stocchiero Silvia, Fossati Piero, Engwall Erik, Georg Dietmar, Stock Markus, Knäusl Barbara
Medical University of Vienna, Department of Radiation Oncology, Vienna, Austria.
MedAustron Ion Therapy Centre, Wiener Neustadt, Austria.
Phys Imaging Radiat Oncol. 2023 Jul 20;27:100473. doi: 10.1016/j.phro.2023.100473. eCollection 2023 Jul.
Retrospective log file-based analysis provides the actual dose delivered based on the patient's breathing and the daily beam-delivery dynamics. To predict the motion sensitivity of the treatment plan on a patient-specific basis before treatment start a prospective tool is required. Such a parameter-based tool has been investigated with the aim to be used in clinical routine. 4D dose calculations (4DDC) were performed for seven cancer patients with small breathing motion treated with scanned pulsed proton beams. Validation of the parameter-based 4DDC (p-4DDC) method was performed with an anthropomorphic phantom and patient data employing measurements and a log file-based 4DDC tool. The dose volume histogram parameters () were investigated for the target and the organs at risk, compared to static and the file-based approach. The difference between the measured and the p-4DDC dose was within the deviation of the measurements. The maximum deviation was 0.4Gy. For the planning target volume varied up to 15% compared to the static scenario, while the results from the log file and p-4DDC agreed within 2%. For the liver patients, deviated up to 35% compared to static and 10% comparing the two 4DDC tools, while for the pancreas patients the varied up to 45% and 11%, respectively. The results showed that p-4DDC could be used prospectively. The next step will be the clinical implementation of the p-4DDC tool, which can support a decision to either adapt the treatment plan or apply motion mitigation strategies.
基于回顾性日志文件的分析可根据患者的呼吸和每日射束输送动态提供实际输送剂量。为了在治疗开始前基于患者个体情况预测治疗计划的运动敏感性,需要一种前瞻性工具。已对这样一种基于参数的工具进行了研究,旨在将其用于临床常规。对7例接受扫描脉冲质子束治疗且呼吸运动较小的癌症患者进行了4D剂量计算(4DDC)。使用拟人化体模和患者数据,通过测量以及基于日志文件的4DDC工具对基于参数的4DDC(p-4DDC)方法进行了验证。针对靶区和危及器官研究了剂量体积直方图参数(),并与静态方法和基于文件的方法进行了比较。测量剂量与p-4DDC剂量之间的差异在测量偏差范围内。最大偏差为0.4Gy。与静态方案相比,计划靶体积的差异高达15%,而日志文件和p-4DDC的结果在2%以内一致。对于肝脏患者,与静态方法相比偏差高达35%,两种4DDC工具之间的偏差为10%,而对于胰腺患者,差异分别高达45%和11%。结果表明p-4DDC可用于前瞻性分析。下一步将是p-4DDC工具的临床应用,它可以支持决定是调整治疗计划还是应用运动缓解策略。