Nagata Mayumi, Matsushima Hiroyuki, Mukai Koichiro, Senoo Tadashi, Nishi Okihiro
Department of Ophthalmology, Dokkyo Medical University, 880 Kitakobayashi, Mibu, Tochigi, 321-0293, Japan.
Nishi Eye Hospital, Osaka, Japan.
Jpn J Ophthalmol. 2023 Nov;67(6):693-698. doi: 10.1007/s10384-023-01013-7. Epub 2023 Aug 3.
To verify the anterior capsule opacification (ACO) and contraction (ACC) of the ZCB00V intraocular lens (IOL), made of the same material as the AR40e with a high ACC rate.
Retrospective cohort study.
We evaluated 35 patients at 1 week, 1, 3 and 6 months post phacoemulsification with either a ZCB00V (n = 35) or FY-60AD (n = 34) IOL implantation. The ACC rate was calculated using retroillumination images of the anterior segment, and the ACO was measured using anterior segment photographs and image analysis software. The contact grade between the IOL and anterior capsule was estimated from the Pentacam images.
The postoperative ACC rates (mean ± standard deviation) at 3 months were 1.03%±2.54% for the ZCB00V and, and 7.12%±9.47% for the FY-60AD. The ZCB00V-implanted eyes showed a significantly lower postoperative ACC at 1 week, 3 months, and 6 months (P < 0.01). On the other hand, the FY-60AD-implanted eyes had more pronounced ACO, and a significantly larger area of opacification (62.24%±21.32% vs. 16.90%±8.34%; P = 0.0005). Pentacam analysis revealed a space between the anterior capsule and IOL surface in the ZCB00V-implanted eyes, whereas the anterior capsule firmly adhered to the IOL surface in the FY-60AD-implanted eyes.
The ACC and ACO were significantly lower in eyes with ZCB00V IOLs compared to those with the FY-60AD. The anterior segment image analysis revealed that the elevated anterior rim of the ZCB00V IOL prevented adhesion between the anterior capsule and IOL optic surface, suggesting an open capsule effect.
验证ZCB00V人工晶状体(IOL)的前囊膜混浊(ACO)和收缩(ACC)情况,该人工晶状体与ACC发生率较高的AR40e采用相同材料制成。
回顾性队列研究。
我们评估了35例接受超声乳化白内障吸除术并植入ZCB00V人工晶状体(n = 35)或FY - 60AD人工晶状体(n = 34)的患者,分别在术后1周、1个月、3个月和6个月进行评估。使用眼前节的后照图像计算ACC发生率,并使用眼前节照片和图像分析软件测量ACO。根据Pentacam图像估计人工晶状体与前囊膜之间的接触等级。
ZCB00V人工晶状体组术后3个月的ACC发生率(平均值±标准差)为1.03%±2.54%,FY - 60AD人工晶状体组为7.12%±9.47%。植入ZCB00V人工晶状体的眼睛在术后1周、3个月和6个月时的ACC明显较低(P < 0.01)。另一方面,植入FY - 60AD人工晶状体的眼睛ACO更明显,混浊面积显著更大(62.24%±21.32%对16.90%±8.34%;P = 0.0005)。Pentacam分析显示,植入ZCB00V人工晶状体的眼睛前囊膜与人工晶状体表面之间存在间隙,而植入FY - 60AD人工晶状体的眼睛前囊膜牢固地附着在人工晶状体表面。
与植入FY - 60AD人工晶状体的眼睛相比,植入ZCB00V人工晶状体的眼睛ACC和ACO明显更低。眼前节图像分析显示,ZCB00V人工晶状体升高的前缘可防止前囊膜与人工晶状体光学表面之间的粘连,提示存在开放囊袋效应。