J Refract Surg. 2023 Aug;39(8):546-554. doi: 10.3928/1081597X-20230626-01. Epub 2023 Aug 1.
To compare the dynamic vault range (the difference in the central vault height from scotopic to photopic light condition) after implantation of the ICL/TICL (STAAR Surgical) and Eyecryl phakic/Eyecryl phakic toric intraocular lens (IOL) (Biotech Healthcare).
This retrospective study included patients with myopia or myopic astigmatism eligible for phakic IOL implantation with either the ICL/TICL or Eyecryl phakic/Eyecryl phakic toric IOL. Vault changes in varying light conditions (scotopic, mesopic, and photopic) were assessed using an anterior segment optical coherence tomography-based tomographer and dynamic vault range (DVR) was compared between the two groups.
A total of 60 eyes from 36 patients (30 eyes in each group) with a mean age of 28.63 ± 6.36 years were included. The mean postoperative follow-up at the time of assessment was 9.4 ± 5.3 and 8.9 ± 5.28 months ( = .75) in the ICL and Eyecryl groups, respectively. The mean values of scotopic, mesopic, and photopic vault were 490.56 ± 238.64, 453.56 ± 224.30, and 373.96 ± 200.24 μm in the ICL group and 515.46 ± 174.34, 490.26 ± 184.04, 450.43 ± 173.92 μm in the Eyecryl group ( .32, .24, and .05, respectively). The DVR was 116.6 ± 59.29 μm in the ICL group versus 65.03 ± 31.78 μm in the Eyecryl group ( < .001).
The Eyecryl phakic IOL showed significantly fewer light-induced changes in the central vault height (DVR) compared to the ICL, which may be attributed to the difference in the material of the two phakic IOL models. This may be clinically significant in eyes with low postoperative vaults with respect to their follow-up and risk assessment of cataractogenesis in the long term. .
比较植入 ICL/TICL(STAAR Surgical)和 Eyecryl 有晶状体眼人工晶状体(IOL)(Biotech Healthcare)后动态中央拱顶高度(从暗视到明视时中央拱顶高度的差异)。
这项回顾性研究纳入了适合植入有晶状体眼 IOL 的近视或近视散光患者,分别植入 ICL/TICL 或 Eyecryl 有晶状体眼人工晶状体。使用基于眼前节光学相干断层扫描的断层扫描仪评估不同光照条件(暗视、中间光和明视)下的拱顶变化,并比较两组之间的动态拱顶范围(DVR)。
共纳入 36 名患者(每组 30 只眼)的 60 只眼,平均年龄为 28.63±6.36 岁。在评估时的平均术后随访时间分别为 ICL 组 9.4±5.3 个月和 Eyecryl 组 8.9±5.28 个月( =.75)。ICL 组的暗视、中间光和明视中央拱顶高度的平均值分别为 490.56±238.64、453.56±224.30 和 373.96±200.24 μm,Eyecryl 组分别为 515.46±174.34、490.26±184.04 和 450.43±173.92 μm( =.32,.24 和.05)。ICL 组的 DVR 为 116.6±59.29 μm,而 Eyecryl 组为 65.03±31.78 μm( <.001)。
与 ICL 相比,Eyecryl 有晶状体眼 IOL 中央拱顶高度(DVR)的光诱导变化明显较少,这可能归因于两种有晶状体眼 IOL 模型的材料差异。对于术后拱顶较低的眼睛,这在其随访和长期白内障发生风险评估方面可能具有重要的临床意义。