Li Lianghua, Chen Ruohua, Wen Jun, Yang Xuefei, Hu Debin, Sun Hongyan, Ge Qi, Ng Yee Ling, Zhou Yun, Wan Liangrong, Chen Yumei, Wei Weijun, Liu Jianjun
Department of Nuclear Medicine, Ren Ji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Central Research Institute, United Imaging Healthcare Group Co., Ltd, Shanghai, China.
Quant Imaging Med Surg. 2023 Aug 1;13(8):5230-5241. doi: 10.21037/qims-22-1341. Epub 2023 Jul 11.
Total variation regularized expectation maximization (TVREM) reconstruction algorithm on the image quality of gallium (GA) prostate-specific membrane antigen-11 ([Ga]Ga-PSMA-11) total-body positron emission tomography/computed tomography (PET/CT).
Images of a phantom with small hot sphere inserts and the total-body PET/CT scans of 51 prostate cancer patients undergoing [Ga]Ga-PSMA-11 were reconstructed using TVREM with 5 different penalization factors between 0.09 and 0.45 and for 20-, 40-, 60-, 120-, and 300-second acquisition, respectively. As a comparison, the same data were also reconstructed using the ordered subset expectation maximization (OSEM) with 3 iterations, 20 subsets, and 300 second acquisition. The contrast recovery coefficients (CRC) and background variability (BV) of the phantom, the tumor-to-background ratios (TBR), the contrast recovery (CR) ratio, the image noise of the liver, and maximum standard uptake value (SUV) of the lesions were calculated to evaluate the image quality. The clinical performance of the images was evaluated by 2 radiologists with a 5-point scale (1-poor, 5-excellent).
The TVREM reconstructions groups fwith 120 second acquisition and the penalization of 0.27 to 0.45 showed the best performance in terms of CR, TBR, image noise, and the gain of SUV compared to that obtained in the OSEM 300 second group. Even the image noise of the TVREM 120 second group with a penalization factor of 0.27 and 0.36 was comparable to the OSEM 300 second group; the lesions' SUV increased by 28% whereas the image noise decreased by 5% and 14%, respectively. The TVREM 120 second group with a penalization factor of 0.36 (5.00±0.00) had the highest qualitative score that equaled OSEM and TVREM for the 300 second (P>0.05) group.
Our study has shown the potential of the TVREM reconstruction algorithm with optimized penalization factors to achieve comparable [Ga]Ga-PSMA-11 total-body PET/CT image quality with a shorter acquisition time, compared with the conventional OSEM reconstruction algorithm.
总变差正则期望最大化(TVREM)重建算法对镓(GA)前列腺特异性膜抗原-11([Ga]Ga-PSMA-11)全身正电子发射断层扫描/计算机断层扫描(PET/CT)图像质量的影响。
使用TVREM对带有小热球插入物的体模图像以及51例接受[Ga]Ga-PSMA-11检查的前列腺癌患者的全身PET/CT扫描图像进行重建,分别采用5个介于0.09和0.45之间的不同惩罚因子,采集时间分别为20秒、40秒、60秒、120秒和300秒。作为对照,相同数据也采用有序子集期望最大化(OSEM)进行重建,迭代3次,子集数为20,采集时间为300秒。计算体模的对比恢复系数(CRC)和背景变异性(BV)、肿瘤与背景比值(TBR)、对比恢复(CR)率、肝脏图像噪声以及病变的最大标准摄取值(SUV),以评估图像质量。由2名放射科医生采用5分制(1分-差,5分-优)对图像的临床性能进行评估。
与OSEM 300秒组相比,采集时间为120秒且惩罚因子为0.27至0.45的TVREM重建组在CR、TBR、图像噪声以及SUV增益方面表现最佳。即使惩罚因子为0.27和0.36的TVREM 120秒组的图像噪声也与OSEM 30秒组相当;病变的SUV增加了28%,而图像噪声分别降低了5%和14%。惩罚因子为0.36的TVREM 120秒组(5.00±0.00)的定性评分最高,与OSEM和300秒的TVREM组相当(P>0.05)。
我们的研究表明,与传统的OSEM重建算法相比具有优化惩罚因子的TVREM重建算法有可能在更短的采集时间内获得相当质量 的[Ga]Ga-PSMA-11全身PET/CT图像。