A new echocardiographic model for quantifying three-dimensional endocardial surface area.

作者信息

Guyer D E, Gibson T C, Gillam L D, King M E, Wilkins G T, Guerrero J L, Weyman A E

出版信息

J Am Coll Cardiol. 1986 Oct;8(4):819-29. doi: 10.1016/s0735-1097(86)80423-5.

Abstract

A new technique for quantitatively mapping the three-dimensional left ventricular endocardial surface was developed, using measurements from standard cross-sectional echocardiographic images. To validate the accuracy of this echocardiographic mapping technique in an animal model, the endocardial areas of 15 excised canine ventricles were calculated using measurements made from echocardiographic studies of the hearts and compared with areas determined with latex casts of the same ventricles. Close correlation (r = 0.87, p less than 0.001) between these two measures of endocardial area provided preliminary confirmation of the accuracy of the maps. To further characterize the mapping algorithm, it was translated into computer format and used to map the surfaces of idealized hemiellipsoids. Areas measured with this mapping technique closely approximated the actual areas of idealized surfaces with a wide spectrum of shapes; maps were particularly accurate for ellipsoids with shapes similar to those of undistorted human ventricles. Also, the accuracies of area calculations were relatively insensitive to deviation from the assumed positions of the echocardiographic short-axis planes. Finally, although the accuracy of the mapping technique improved as data from more transverse planes were added, the procedure proved reliable for estimating surface areas when data from only three planes were used. These studies confirm the accuracy of the echocardiographic mapping technique, and they suggest that the resulting planar plots might be useful as templates for localizing and quantifying the overall extent of abnormal wall motion.

摘要

利用标准横截面超声心动图图像的测量数据,开发了一种定量绘制三维左心室心内膜表面的新技术。为了在动物模型中验证这种超声心动图测绘技术的准确性,使用从心脏的超声心动图研究中获得的测量数据计算了15个切除的犬心室的心内膜面积,并与用相同心室的乳胶铸型确定的面积进行了比较。这两种心内膜面积测量方法之间的密切相关性(r = 0.87,p < 0.001)初步证实了这些图谱的准确性。为了进一步表征测绘算法,将其转换为计算机格式并用于绘制理想化半椭球体的表面。用这种测绘技术测量的面积与各种形状的理想化表面的实际面积非常接近;对于形状类似于未变形人体心室的椭球体,图谱特别准确。此外,面积计算的准确性对超声心动图短轴平面假设位置的偏差相对不敏感。最后,尽管随着更多横向平面的数据加入,测绘技术的准确性有所提高,但当仅使用三个平面的数据时,该程序被证明可可靠地估计表面积。这些研究证实了超声心动图测绘技术的准确性,并表明所得的平面图可能作为定位和量化异常壁运动总体范围的模板有用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验