Suppr超能文献

中央和周边巩膜接触镜引起的角膜水肿。

Central and peripheral scleral lens-induced corneal oedema.

作者信息

Iqbal Asif, Fisher Damien, Alonso-Caneiro David, Collins Michael J, Vincent Stephen J

机构信息

Contact Lens and Visual Optics Laboratory, School of Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.

School of Science, Technology and Engineering, University of Sunshine Coast, Petrie, Queensland, Australia.

出版信息

Ophthalmic Physiol Opt. 2024 Jun;44(4):792-800. doi: 10.1111/opo.13221. Epub 2023 Aug 25.

Abstract

PURPOSE

To quantify the magnitude of central and peripheral scleral lens-induced corneal oedema for a range of fluid reservoir thicknesses, and to compare these experimental results with theoretical models of corneal oedema both with and without limbal metabolic support (i.e., the lateral transport of metabolites and the influence of the limbal vasculature).

METHODS

Ten young healthy participants wore scleral lenses (KATT™, Capricornia Contact Lenses) fitted with low (mean 141 μm), medium (482 μm) and high (718 μm) central fluid reservoir thickness values across three separate study visits. The scleral lens thickness, fluid reservoir thickness and stromal corneal oedema were measured using optical coherence tomography. Oedema was quantified across the central (0-2.5 mm from the corneal apex) and peripheral (1.25-3 mm from the scleral spur) cornea. Experimental data were compared with published theoretical models of central to peripheral corneal oedema.

RESULTS

Stromal oedema varied with fluid reservoir thickness (p < 0.001) for both central and peripheral regions. The mean (standard deviation) stromal oedema was greater for the medium (2.08 (1.21)%) and high (2.22 (1.31)%) fluid reservoir thickness conditions compared to the low condition (1.00 (1.01)%) (p ≤ 0.01). Stromal oedema gradually increased from the corneal centre to the periphery by ~0.3% on average (relative increase of 18%), but the change did not reach statistical significance. This trend of increasing, rather than decreasing, oedema towards the limbus is consistent with theoretical modelling of peripheral oedema without metabolic support from the limbus.

CONCLUSIONS

The central and peripheral cornea displayed a similar magnitude of oedema, with increasing levels observed for medium and high fluid reservoir thicknesses. The gradual increase in oedema towards the limbus is consistent with a 'without limbal metabolic support' theoretical model.

摘要

目的

量化一系列不同储液腔厚度的巩膜镜引起的中央和周边角膜水肿程度,并将这些实验结果与有无角膜缘代谢支持(即代谢物的侧向转运和角膜缘血管系统的影响)的角膜水肿理论模型进行比较。

方法

10名年轻健康受试者在三次独立的研究访视中佩戴了中央储液腔厚度分别为低(平均141μm)、中(482μm)和高(718μm)的巩膜镜(KATT™,摩羯座隐形眼镜公司)。使用光学相干断层扫描测量巩膜镜厚度、储液腔厚度和角膜基质水肿。在中央角膜(距角膜顶点0 - 2.5mm)和周边角膜(距巩膜突1.25 - 3mm)测量水肿情况。将实验数据与已发表的中央至周边角膜水肿理论模型进行比较。

结果

中央和周边区域的角膜基质水肿均随储液腔厚度变化(p < 0.001)。与低储液腔厚度情况(1.00(1.01)%)相比,中(2.08(1.21)%)和高(2.22(1.31)%)储液腔厚度条件下的平均(标准差)角膜基质水肿更大(p≤0.01)。角膜基质水肿从角膜中心到周边平均逐渐增加约0.3%(相对增加18%),但该变化未达到统计学显著性。这种向角膜缘水肿增加而非减少的趋势与无角膜缘代谢支持的周边水肿理论模型一致。

结论

中央和周边角膜显示出相似程度的水肿,中高储液腔厚度时水肿水平增加。向角膜缘水肿逐渐增加与“无角膜缘代谢支持”的理论模型一致。