Yu Li-Hua, Zhuo Ran, Song Guan-Xing, Lin Meng, Jin Wan-Qing
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China.
School of Ophthalmology & Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China.
Front Med (Lausanne). 2023 Aug 10;10:1207328. doi: 10.3389/fmed.2023.1207328. eCollection 2023.
Ocular pathology may be reduced by slowing myopia progression. The purpose of this study was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to control high myopia by comparing the efficacy of multifocal RGP lenses and single-vision spectacles for high myopia control.
The medical records of children fitted with spectacles or multifocal rigid gas-permeable lenses between January 2018 and May 2020 were retrospectively reviewed. Children (5-17 years) with non-cycloplegic spherical equivalent refraction of ≤ -6.00 D or spherical equivalent refraction > - 6.00 D with baseline axial length ≥ 26.5 mm, and astigmatism of ≥ -2.00 D were included. Axial length and refraction were measured at baseline, before fitting the participants with multifocal rigid gas-permeable lenses or spectacles, and at 1- and 2-year follow-up visits. Changes in axial length were compared between the groups.
Among the 77 children with 1-year follow-up data, the mean axial elongation was 0.20 ± 0.17 mm and 0.21 ± 0.14 mm in the multifocal rigid gas-permeable and control groups, respectively, without significant differences between groups ( = 0.004, = 0.835). Among the 41 patients who completed 2 years of follow-up, the mean axial elongation values in the multifocal rigid gas-permeable and control groups were 0.21 ± 0.15 mm and 0.24 ± 0.13 mm, respectively, at the 1-year follow-up, and 0.37 ± 0.27 mm and 0.43 ± 0.23 mm, respectively, at the 2-year follow-up, without significant between-group differences at either time point ( = 0.224).
Axial length increased at a similar rate in both the control (spectacles) and multifocal rigid gas-permeable lens groups, suggesting that multifocal rigid gas-permeable lenses have no significant impact on controlling high myopia progression compared with spectacles.
减缓近视进展可能会减轻眼部病理变化。本研究的目的是通过比较多焦点硬性透气性(RGP)隐形眼镜和单焦点眼镜控制高度近视的效果,评估一种新型定制设计的RGP隐形眼镜控制高度近视的潜力。
回顾性分析2018年1月至2020年5月期间佩戴眼镜或多焦点硬性透气性隐形眼镜的儿童的病历。纳入年龄在5至17岁之间、非散瞳等效球镜度≤-6.00 D或等效球镜度>-6.00 D且基线眼轴长度≥26.5 mm、散光≥-2.00 D的儿童。在基线时、为参与者佩戴多焦点硬性透气性隐形眼镜或眼镜之前以及随访1年和2年时测量眼轴长度和屈光度数。比较两组之间眼轴长度的变化。
在有1年随访数据的77名儿童中,多焦点硬性透气性隐形眼镜组和对照组的平均眼轴伸长分别为0.20±0.17 mm和0.21±0.14 mm,两组之间无显著差异(=0.004,=0.835)。在完成2年随访的41名患者中,多焦点硬性透气性隐形眼镜组和对照组在1年随访时的平均眼轴伸长值分别为0.21±0.15 mm和0.24±0.13 mm,在2年随访时分别为0.37±0.27 mm和0.43±0.23 mm,两个时间点两组之间均无显著差异(=0.224)。
对照组(眼镜)和多焦点硬性透气性隐形眼镜组的眼轴长度以相似的速率增加,这表明与眼镜相比,多焦点硬性透气性隐形眼镜对控制高度近视进展没有显著影响。