Suppr超能文献

种植体直径对犬模型早期种植体稳定性和骨整合的影响。

Effects of Implant Diameter on Implant Stability and Osseointegration in the Early Stage in a Dog Model.

出版信息

Int J Oral Maxillofac Implants. 2023 Jul-Aug;38(4):757-767. doi: 10.11607/jomi.10089.

Abstract

To determine the optimal implant diameter under limited bone width by comparing the effects of implants with different diameters on implant stability, peri-implant bone stability, and osseointegration. In addition, to evaluate the reliability of resonance frequency analysis (RFA) in detecting osseointegration and marginal bone level (MBL). Mandibular premolars and first molars of seven beagle dogs were extracted. After 8 weeks, their mandibular models and radiographic information were collected to fabricate implant templates. Implant sites were randomly divided into three groups according to diameter: Ø3.3, Ø4.1, and Ø4.8 mm. Implant stability quotient (ISQ) measurement and radiographic evaluation were performed after surgery (baseline) and at 4, 8, and 12 weeks. Three dogs were euthanized at 4 weeks to observe osteogenesis and implant-tissue interface biology. Four dogs were euthanized at 12 weeks to observe osseointegration. Hard tissue sections were prepared to analyze osteogenesis (fluorescence double labeling) and osseointegration (methylene blue-acid fuchsin staining). At baseline and at 4, 8, and 12 weeks, the ISQ values of Ø4.1- and Ø4.8-mm implants did not differ ( > .05), but both had higher values than the Ø3.3-mm implants ( < .05). The mean marginal bone resorption (MBR) associated with Ø3.3-, Ø4.1-, and Ø4.8-mm implants was 0.65 ± 0.58 mm, 0.37 ± 0.28 mm, and 0.73 ± 0.37 mm, respectively. The buccal MBR of Ø4.8-mm implants was significantly higher than that of Ø4.1-mm implants ( < .05). The bone-to-implant contact (BIC) percentage at 12 weeks did not differ for any group ( > .05). The correlation coefficients between the ISQ and MBL of the Ø3.3-, Ø4.1-, and Ø4.8-mm implants were -0.84 ( < .01), -0.90 ( < .001), and -0.93 ( < .001), respectively, while that between the ISQ and BIC was 0.15 ( > .05). During the early healing stage, the performance of Ø4.1- and Ø4.8-mm implants in terms of implant stability was better than that of Ø3.3-mm implants. Implant diameter may not influence BIC percentage. RFA can be used to evaluate implant stability and MBL but is not suitable to assess the degree of osseointegration.

摘要

为了通过比较不同直径种植体对种植体稳定性、种植体周围骨稳定性和骨整合的影响,确定在有限骨宽度下的最佳种植体直径。此外,评估共振频率分析(RFA)在检测骨整合和边缘骨水平(MBL)方面的可靠性。

从 7 只比格犬中拔出下颌前磨牙和第一磨牙。8 周后,收集其下颌模型和影像学信息以制作种植体模板。根据直径将种植部位随机分为三组:Ø3.3、Ø4.1 和 Ø4.8mm。术后(基线)及 4、8 和 12 周时进行种植体稳定性测量和影像学评估。4 周时处死 3 只狗以观察成骨和种植体-组织界面生物学。12 周时处死 4 只狗以观察骨整合。制备硬组织切片以分析成骨(荧光双标记)和骨整合(亚甲蓝-酸性品红染色)。

在基线时以及 4、8 和 12 周时,Ø4.1 和 Ø4.8mm 种植体的 ISQ 值没有差异(>.05),但均高于 Ø3.3mm 种植体(<.05)。与 Ø3.3、Ø4.1 和 Ø4.8mm 种植体相关的平均边缘骨吸收(MBR)分别为 0.65 ± 0.58mm、0.37 ± 0.28mm 和 0.73 ± 0.37mm。4.8mm 种植体颊侧 MBR 明显高于 4.1mm 种植体(<.05)。12 周时,任何组的骨-种植体接触(BIC)百分比均无差异(>.05)。Ø3.3、Ø4.1 和 Ø4.8mm 种植体的 ISQ 与 MBL 的相关系数分别为-0.84(<.01)、-0.90(<.001)和-0.93(<.001),而 ISQ 与 BIC 的相关系数为 0.15(>.05)。

在早期愈合阶段,Ø4.1 和 Ø4.8mm 种植体在种植体稳定性方面的表现优于 Ø3.3mm 种植体。种植体直径可能不会影响 BIC 百分比。RFA 可用于评估种植体稳定性和 MBL,但不适合评估骨整合程度。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验