Abstract

Conventional cage and plate (CCP) implants usually used in ACDF surgery, do have limitations such as the development of postoperative dysphagia, adjacent segment degeneration, and soft tissue injury. To reduce the risk of these complications, zero-profile stand-alone cage were developed. We used finite-element modeling to compare the total von Mises stress applied to the bone, disc, endplate, cage and screw when using CCP and ZPSC implants. A 3-dimensional FE (Finite element) analysis was performed to investigate the effects of the CCP implant and ZPSC on the C3 ~ T1 vertebrae. We confirmed that the maximum von Mises stress applied with ZPSC implants was more than 2 times greater in the endplate than that applied with CCP implants. The 3D analysis of the ZPSC model von Mises stress measurements of screw shows areas of higher stress in red. Although using ZPSC implants in ACDF reduces CCP implant-related sequalae such as dysphagia, we have shown that greater von Mises stress is applied to the endplate, and screw when using ZPSC implants. This may explain the higher subsidence rate associated with ZPSC implant use in ACDF. When selecting an implant in ACDF, surgeons should consider patient characteristics and the advantages and disadvantages of each implant type.

摘要

传统的笼和板(CCP)植入物通常用于 ACDF 手术,但存在一些局限性,如术后吞咽困难、相邻节段退变和软组织损伤。为了降低这些并发症的风险,开发了无轮廓独立笼。我们使用有限元建模比较了使用 CCP 和 ZPSC 植入物时骨、椎间盘、终板、笼和螺钉承受的总 von Mises 应力。进行了三维有限元(Finite element)分析,以研究 CCP 植入物和 ZPSC 对 C3~T1 椎体的影响。我们证实,与 CCP 植入物相比,ZPSC 植入物施加在终板上的最大 von Mises 应力超过 2 倍。ZPSC 模型 von Mises 应力测量螺钉的三维分析显示红色区域的应力较高。尽管在 ACDF 中使用 ZPSC 植入物可以减少与 CCP 植入物相关的后遗症,如吞咽困难,但我们已经表明,在使用 ZPSC 植入物时,终板和螺钉承受的 von Mises 应力更大。这可能解释了在 ACDF 中使用 ZPSC 植入物时更高的沉降率。在选择 ACDF 中的植入物时,外科医生应考虑患者的特点和每种植入物类型的优缺点。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a242/10516908/d6d7af652051/41598_2023_43086_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验