Nuttall Rachel, El Mir Aya, Jäger Cilia, Letz Svenja, Wohlschläger Afra, Schneider Gerhard
Department of Anesthesiology and Intensive Care, School of Medicine, Technical University of Munich, Klinikum rechts der Isar, Munich 81675, Germany.
New York University Abu Dhabi, Engineering Division, Saadiyat Marina District, Abu Dhabi, United Arab Emirates.
MethodsX. 2023 Sep 14;11:102376. doi: 10.1016/j.mex.2023.102376. eCollection 2023 Dec.
Electroencephalography (EEG) data, acquired simultaneously with magnetic resonance imaging (MRI), must be corrected for artefacts related to MR gradient switches (GS) and the cardioballistic (CB) effect. Canonical approaches require additional signal acquisition for artefact detection (e.g., MR volume onsets, ECG), without which the EEG data would be rendered uncleanable from these artefacts.•We present two broadly applicable methods for artefact detection based on peak detection combined with temporal constraints with respect to periodicity directly from the EEG data itself; no additional signals are required. We validated the performance of our methods versus the two canonical approaches for detection of GS/CB artefact, respectively, on 26 healthy human EEG-functional MRI resting-state datasets. Utilising various performance metrics, we found our methods to perform as well as - and sometimes better than - the canonical standard approaches. With as little as one EEG channel recording, our methods can be applied to detect GS/CB artefacts in EEG data acquired simultaneously with MRI in the absence of MR volume onsets and/or an ECG recording. The detected artefact onsets can then be fed into the standard artefact correction software.
与磁共振成像(MRI)同时采集的脑电图(EEG)数据,必须针对与MR梯度切换(GS)和心弹效应(CB)相关的伪迹进行校正。传统方法需要额外采集信号用于伪迹检测(例如,MR容积起始点、心电图),否则EEG数据将无法从这些伪迹中清理干净。•我们提出了两种广泛适用的伪迹检测方法,它们基于峰值检测并结合直接从EEG数据本身得出的关于周期性的时间约束;无需额外信号。我们分别在26个健康人类EEG - 功能MRI静息态数据集上,将我们的方法与检测GS/CB伪迹的两种传统方法的性能进行了验证。利用各种性能指标,我们发现我们的方法表现与传统标准方法相当,有时甚至更好。只需最少一个EEG通道记录,我们的方法就可应用于在没有MR容积起始点和/或心电图记录的情况下,检测与MRI同时采集的EEG数据中的GS/CB伪迹。然后,检测到的伪迹起始点可输入到标准伪迹校正软件中。