2nd Department of Radiology, University General Hospital "Attikon", 1 Rimini Street, National and Kapodistrian University of Athens, Chaidari, Greece.
Joint Department of Physics, The Royal Marsden NHS Foundation Trust, London, UK.
J Appl Clin Med Phys. 2023 Nov;24(11):e14085. doi: 10.1002/acm2.14085. Epub 2023 Oct 4.
Comparing dose distributions is a routine task in radiotherapy, mainly in patient-specific quality assurance (PSQA). Currently, the evaluation of the dose distributions is being performed mainly with statistical methods, which could underestimate the clinical importance of the spotted differences, as per the literature.
This paper aims to provide proof-of-concept for a novel dose distribution comparison method based on the difference of the isodose surfaces. The new method connects acceptance tolerance to QA limitations (equipment capabilities) and integrates a clinical approach into the analysis procedure.
The distance of dose points from the isocenter can be used as a function to define the shape of an isodose surface expressed as a histogram. Isodose surface differences (ISD) are defined as the normalized differences of reference and evaluated surface histograms plotted against their corresponding isodose. Acceptance tolerances originate from actual QA tolerances and are presented clinically intuitively. The ISD method was compared to the gamma index using intentionally erroneous VMAT and IMRT plans.
Results revealed that the ISD method is sensitive to all errors induced in the plans. Discrepancies are presented per isodose, enabling the evaluation of the plan in two regions representing PTV and Normal Tissue. ISD manages to flag errors that would remain undetected under the gamma analysis.
The ISD method is a meaningful, QA-related, registration-free, and clinically oriented technique of dose distribution evaluation. This method can be used either as a standalone or an auxiliary tool to the well-established evaluation procedures, overcoming significant limitations reported in the literature.
比较剂量分布是放射治疗中的一项常规任务,主要用于患者特定的质量保证(PSQA)。目前,剂量分布的评估主要采用统计方法,但根据文献报道,这种方法可能低估了差异的临床重要性。
本文旨在提供一种基于等剂量曲面差异的新型剂量分布比较方法的概念验证。该新方法将验收公差与 QA 限制(设备能力)联系起来,并将临床方法集成到分析过程中。
剂量点距等中心点的距离可用作定义等剂量曲面形状的函数,其表示为直方图。等剂量曲面差异(ISD)定义为参考和评估表面直方图的归一化差异,相对于其相应的等剂量绘制。验收公差源于实际的 QA 公差,并以临床直观的方式呈现。将 ISD 方法与伽马指数进行了比较,使用了故意错误的 VMAT 和 IMRT 计划。
结果表明,ISD 方法对计划中引入的所有误差都很敏感。每个等剂量都呈现出差异,从而可以评估代表 PTV 和正常组织的两个区域的计划。ISD 设法标记了伽马分析仍未检测到的错误。
ISD 方法是一种有意义的、与 QA 相关的、无配准且面向临床的剂量分布评估技术。该方法可以作为独立的或辅助工具用于既定的评估程序,克服了文献中报道的一些重大局限性。